Utah septic rules
Utah Department of Environmental Quality, Division of Water Quality (DWQ), Onsite Wastewater Program · Onsite Wastewater Program. Statute: Utah Code Title 19, Chapter 5 (Water Quality Act), 19-5-104. Rule: Utah Admin. Code R317-4 (Onsite Wastewater Systems); R317-11 (Certification of Onsite Professionals); R317-5 (Large Underground Wastewater Disposal Systems).
For homeowners in Utah
- Local agencies permit septic systems under the state rule (Utah Admin. Code R317-4 (Onsite Wastewater Systems); R317-11 (Certification of Onsite Professionals); R317-5 (Large Underground Wastewater Disposal Systems)). Find yours in the county list below.
- The state rule does not require a maintenance contract for aerobic units.
Counties
The office that permits septic systems in each county, with the estimated number of systems and how many have an aerator or a pump. ● marks counties whose pump and aerator figures come from county records; the rest spread the state estimate.
What the state rule requires
- Administering body
- Utah Water Quality Board / DWQ adopts R317-4, certifies onsite professionals (R317-11), approves septic tank designs and permits large underground systems; the 13 local health departments have jurisdiction to administer R317-4, issue permits, may issue operating permits and must run an alternative onsite system program with annual reports to DWQ
R317-4-1(1), (4), (5): “This rule is authorized by Title 19, Chapter 5, Water Quality Act. ... Local health departments have jurisdiction to administer this rule. ... Local health departments shall administer an alternative onsite wastewater system program.” source
- Administration model
- State rule, local agencies permit
- Statute
- Utah Code 19-5-104
- Rule
- Utah Admin. Code R317-4 (last change 2023-06-29)
- License required
- Yes
R317-4 (plan submittal); R317-4 alternative system design: “Any plans and specifications shall be prepared by an individual certified in accordance with Rule R317-11. ... Each system that uses this method shall be designed by a person certified at Level 3 in accordance with Rule R317-11.” source
- License classes
- site_evaluator;designer;inspector_general;maintenance_provider
R317-11; DWQ onsite program page: “Level 1: Soil evaluations and percolation testing. Level 2: Design, inspection, and maintenance of conventional underground systems ... Level 3: Design, inspection, and maintenance of alternative or conventional systems ... Each level is valid for up to 3 years ... each certificate carries a $25 fee.” source
- Maintenance contract for aerobic or advanced units
- No
R317-4-1(4)(f): “Nothing contained in this rule shall be construed to prevent local health departments from ... requiring any onsite system within its jurisdiction to be managed by a: (i) responsible management entity overseen by the local health department; (ii) contract service provider overseen by the local health department; or (iii) management district body politic created by the county for operating, maintaining, repairing and monitoring alternative or all onsite wastewater systems.” source
- Homeowner self-maintenance
- Not stated
- Reports go to the authority
- Yes
R317-4-1(5)(b)(iv)-(vi): “inspect any installed alternative onsite wastewater system at frequency specified in this rule, through: (A) the department's staff; (B) contracted service providers; (C) responsible management entity; or (D) a management district ... submit an annual report to the division on or before September 1 for the previous Utah fiscal year's activities showing: (A) the type and number of alternative onsite wastewater systems approved, installed, modified, repaired, failed, and inspected.” source
- Report channel
- Not stated
- Report platform
- Local health department inspects/records alternative systems and reports annually to DWQ by Sept 1 (R317-4-1(5)(b)); no state operator-reporting portal
- Electronic monitoring in the rule
- Alarm requirement only
R317-4-14 Appendix B; holding tank requirements: “When a duplex pump system is designed, controls shall be provided that an alarm shall signal when one of the pumps malfunctions. ... [holding tank] This device shall be either an audible or a visual alarm. Any visual alarm shall be conspicuously mounted.” source
- Monitoring wording
- R317-4-14 Appendix B (Pressure Distribution, Pumps, Controls, and Alarms): when a duplex pump system is designed, controls shall be provided that an alarm shall signal when one of the pumps malfunctions; holding tanks: a device shall be installed on each tank to show when it is within 75% of being full, either an audible or a visual alarm. No telemetry or remote-monitoring provision found.
- Alarm required
- Yes
- Annual operating permit
- No
R317-4-1(4)(b); R317-4 definitions (66): “issuing an operating permit, with a term not exceeding five years, with an inspection showing a satisfactory performance of the permitted system by the department's staff before renewal. ... 'Operating permit' means the permit that authorizes the operation and maintenance of an onsite wastewater system or wastewater holding tank. It may have a fee component that requires periodic renewal.” source
- Fees and periodic programs
- No state operating permit; local health departments may issue an operating permit with a term not exceeding five years, renewed after a satisfactory inspection (R317-4-1(4)(b)), and may require fees for additional inspections; DWQ certification fee $25 per certificate
- Approved product list
- https://lf-public.deq.utah.gov/WebLink/ElectronicFile.aspx?docid=424724&eqdocs=DWQ-2017-003211
DWQ onsite program page: “The page links to a list titled 'Approved Septic Tanks and their Manufacturers'.” source
- Provider list
- https://lf-public.deq.utah.gov/WebLink/ElectronicFile.aspx?docid=454949&eqdocs=DWQ-2017-000801
DWQ onsite program page: “Professional List ... Maintenance Specialists List of Level 2 and/or Level 3 professionals who can be called to perform annual inspections for large underground system operating permits.” source
- Effective date
- 2023-06-29
Systems in service
| Year | What | Low | Mid | High | Method | |
|---|---|---|---|---|---|---|
| 1990 | All systems | 65,403 | 65,403 | 65,403 | 1990 census | source |
| 2021 | All systems | 174,909 | 198,702 | 221,769 | USGS estimate (2025) | source |
Pumps and aerators
Estimated systems in Utah with an aerobic treatment unit (aerator), an effluent or dosing pump, or either. How these are estimated
- With an aerator
- 4,000
- 880 to 11,000 · 2% of all systems
- With a pump
- 22,000
- 9,300 to 51,000 · 11% of all systems
- Pump or aerator
- 24,000
- 9,600 to 55,000 · 12% of all systems
Control panels: about 24,000 installed (8,200 to 61,000), about 240 new a year and 1,600 replacements a year. How panels are estimated
AssumptionNo state figure was found; a regional assumption with a wide range.
No count found. West prior: mostly gravity; alternative systems in county programs (WA counties 2-7% aerobic).
Licensed professionals
No roster parsed yet. The state's list: https://lf-public.deq.utah.gov/WebLink/ElectronicFile.aspx?docid=454949&eqdocs=DWQ-2017-000801
Sources
- Bear River Health Department septic resource lists · Bear River Health Department, pdf
- DWQ Onsite Wastewater Program · Utah DEQ Division of Water Quality, html
- Approved Septic Tanks and their Manufacturers · Utah DEQ DWQ, pdf
- Maintenance Specialists List (Level 2/3 professionals for LUWDS annual inspections) · Utah DEQ DWQ, pdf
- Certified Onsite Wastewater Professionals list (Levels 1-3) · Utah DEQ DWQ, pdf
- Local health department annual alternative-system reports to DWQ (R317-4-1(5)(b)(vi)) · Utah local health departments, pdf
- Utah Admin. Code R317-4 Onsite Wastewater Systems · Utah Office of Administrative Rules, html
- Salt Lake County Health Regulation #13 Wastewater Disposal · Salt Lake County Health Department, pdf
- SWUPHD fee schedule (septic systems) · Southwest Utah Public Health Department, html