Utah septic rules

Utah Department of Environmental Quality, Division of Water Quality (DWQ), Onsite Wastewater Program · Onsite Wastewater Program. Statute: Utah Code Title 19, Chapter 5 (Water Quality Act), 19-5-104. Rule: Utah Admin. Code R317-4 (Onsite Wastewater Systems); R317-11 (Certification of Onsite Professionals); R317-5 (Large Underground Wastewater Disposal Systems).

For homeowners in Utah

  • Local agencies permit septic systems under the state rule (Utah Admin. Code R317-4 (Onsite Wastewater Systems); R317-11 (Certification of Onsite Professionals); R317-5 (Large Underground Wastewater Disposal Systems)). Find yours in the county list below.
  • The state rule does not require a maintenance contract for aerobic units.

Counties

The office that permits septic systems in each county, with the estimated number of systems and how many have an aerator or a pump. ● marks counties whose pump and aerator figures come from county records; the rest spread the state estimate.

CountyPermitting authorityPhoneSystems (USGS mid)With an aeratorPump or aeratorLocal rules
Beaver CountySouthwest Utah Public Health Department, Environmental Health (septic systems)Septics: Washington County 435-986-2580; Iron County 435-865-5155 or 435-865-5154; Kane County 435-296-5477 ext. 3226; Beaver & Garfield 435-865-5158; St. George main 435-673-35281,97239237Yes
Box Elder CountyBear River Health Department, Environmental Health435-792-6570 (Logan Environmental Health Building); 435-792-6500 (Brigham, Tremonton, Randolph offices)10,6922141,283
Cache CountyBear River Health Department, Environmental Health435-792-6570 (Logan Environmental Health Building); 435-792-6500 (Brigham, Tremonton, Randolph offices)13,2282651,587
Carbon CountySoutheast Utah Health Department, Environmental Health435-637-36716,283126754
Daggett CountyTriCounty Health Department, Environmental Health435-247-11771,24225149
Davis CountyDavis County Health Department, Environmental Health Division801-525-51287,613152914
Duchesne CountyTriCounty Health Department, Environmental Health435-247-11778,9051781,069
Emery CountySoutheast Utah Health Department, Environmental Health435-637-36714,97499597
Garfield CountySouthwest Utah Public Health Department, Environmental Health (septic systems)Septics: Washington County 435-986-2580; Iron County 435-865-5155 or 435-865-5154; Kane County 435-296-5477 ext. 3226; Beaver & Garfield 435-865-5158; St. George main 435-673-35284,22084506Yes
Grand CountySoutheast Utah Health Department, Environmental Health435-637-36712,81756338
Iron CountySouthwest Utah Public Health Department, Environmental Health (septic systems)Septics: Washington County 435-986-2580; Iron County 435-865-5155 or 435-865-5154; Kane County 435-296-5477 ext. 3226; Beaver & Garfield 435-865-5158; St. George main 435-673-352810,6362131,276Yes
Juab CountyCentral Utah Public Health Department, Environmental Health435-896-54512,73355328
Kane CountySouthwest Utah Public Health Department, Environmental Health (septic systems)Septics: Washington County 435-986-2580; Iron County 435-865-5155 or 435-865-5154; Kane County 435-296-5477 ext. 3226; Beaver & Garfield 435-865-5158; St. George main 435-673-35285,602112672Yes
Millard CountyCentral Utah Public Health Department, Environmental Health435-896-54515,482110658
Morgan CountyWeber-Morgan Health Department, Environmental Health Division, Water Quality Bureau801-399-71604,07181489Yes
Piute CountyCentral Utah Public Health Department, Environmental Health435-896-54511,15923139
Rich CountyBear River Health Department, Environmental Health435-792-6570 (Logan Environmental Health Building); 435-792-6500 (Brigham, Tremonton, Randolph offices)3,26865392
Salt Lake CountySalt Lake County Health Department, Environmental Health Division, Water Quality Bureau385-468-386210,8642171,304Yes
San Juan CountySan Juan Public Health (San Juan County), Environmental Health435-587-38383,82777459
Sanpete CountyCentral Utah Public Health Department, Environmental Health435-896-54513,38768406
Sevier CountyCentral Utah Public Health Department, Environmental Health435-896-54511,08822131
Summit CountySummit County Health Department, Environmental Health Division (Onsite Wastewater Program)435-333-1500 (fax 435-333-1580); septic records/failing systems 435-336-322414,4902901,739Yes
Tooele CountyTooele County Health Department, Environmental Health435-277-24406,386128766
Uintah CountyTriCounty Health Department, Environmental Health435-247-11779,5091901,141
Utah CountyUtah County Health Department, Environmental Health801-851-752513,7192741,646Yes
Wasatch CountyWasatch County Health Department, Environmental Health435-657-33075,996120720
Washington CountySouthwest Utah Public Health Department, Environmental Health (septic systems)Septics: Washington County 435-986-2580; Iron County 435-865-5155 or 435-865-5154; Kane County 435-296-5477 ext. 3226; Beaver & Garfield 435-865-5158; St. George main 435-673-352824,0694812,888Yes
Wayne CountyCentral Utah Public Health Department, Environmental Health435-896-545189918108
Weber CountyWeber-Morgan Health Department, Environmental Health Division, Water Quality Bureau801-399-71609,5711911,149Yes

What the state rule requires

Administering body
Utah Water Quality Board / DWQ adopts R317-4, certifies onsite professionals (R317-11), approves septic tank designs and permits large underground systems; the 13 local health departments have jurisdiction to administer R317-4, issue permits, may issue operating permits and must run an alternative onsite system program with annual reports to DWQ

R317-4-1(1), (4), (5): “This rule is authorized by Title 19, Chapter 5, Water Quality Act. ... Local health departments have jurisdiction to administer this rule. ... Local health departments shall administer an alternative onsite wastewater system program.” source

Administration model
State rule, local agencies permit
Statute
Utah Code 19-5-104
Rule
Utah Admin. Code R317-4 (last change 2023-06-29)
License required
Yes

R317-4 (plan submittal); R317-4 alternative system design: “Any plans and specifications shall be prepared by an individual certified in accordance with Rule R317-11. ... Each system that uses this method shall be designed by a person certified at Level 3 in accordance with Rule R317-11.” source

License classes
site_evaluator;designer;inspector_general;maintenance_provider

R317-11; DWQ onsite program page: “Level 1: Soil evaluations and percolation testing. Level 2: Design, inspection, and maintenance of conventional underground systems ... Level 3: Design, inspection, and maintenance of alternative or conventional systems ... Each level is valid for up to 3 years ... each certificate carries a $25 fee.” source

Maintenance contract for aerobic or advanced units
No

R317-4-1(4)(f): “Nothing contained in this rule shall be construed to prevent local health departments from ... requiring any onsite system within its jurisdiction to be managed by a: (i) responsible management entity overseen by the local health department; (ii) contract service provider overseen by the local health department; or (iii) management district body politic created by the county for operating, maintaining, repairing and monitoring alternative or all onsite wastewater systems.” source

Homeowner self-maintenance
Not stated
Reports go to the authority
Yes

R317-4-1(5)(b)(iv)-(vi): “inspect any installed alternative onsite wastewater system at frequency specified in this rule, through: (A) the department's staff; (B) contracted service providers; (C) responsible management entity; or (D) a management district ... submit an annual report to the division on or before September 1 for the previous Utah fiscal year's activities showing: (A) the type and number of alternative onsite wastewater systems approved, installed, modified, repaired, failed, and inspected.” source

Report channel
Not stated
Report platform
Local health department inspects/records alternative systems and reports annually to DWQ by Sept 1 (R317-4-1(5)(b)); no state operator-reporting portal
Electronic monitoring in the rule
Alarm requirement only

R317-4-14 Appendix B; holding tank requirements: “When a duplex pump system is designed, controls shall be provided that an alarm shall signal when one of the pumps malfunctions. ... [holding tank] This device shall be either an audible or a visual alarm. Any visual alarm shall be conspicuously mounted.” source

Monitoring wording
R317-4-14 Appendix B (Pressure Distribution, Pumps, Controls, and Alarms): when a duplex pump system is designed, controls shall be provided that an alarm shall signal when one of the pumps malfunctions; holding tanks: a device shall be installed on each tank to show when it is within 75% of being full, either an audible or a visual alarm. No telemetry or remote-monitoring provision found.
Alarm required
Yes
Annual operating permit
No

R317-4-1(4)(b); R317-4 definitions (66): “issuing an operating permit, with a term not exceeding five years, with an inspection showing a satisfactory performance of the permitted system by the department's staff before renewal. ... 'Operating permit' means the permit that authorizes the operation and maintenance of an onsite wastewater system or wastewater holding tank. It may have a fee component that requires periodic renewal.” source

Fees and periodic programs
No state operating permit; local health departments may issue an operating permit with a term not exceeding five years, renewed after a satisfactory inspection (R317-4-1(4)(b)), and may require fees for additional inspections; DWQ certification fee $25 per certificate
Approved product list
https://lf-public.deq.utah.gov/WebLink/ElectronicFile.aspx?docid=424724&eqdocs=DWQ-2017-003211

DWQ onsite program page: “The page links to a list titled 'Approved Septic Tanks and their Manufacturers'.” source

Provider list
https://lf-public.deq.utah.gov/WebLink/ElectronicFile.aspx?docid=454949&eqdocs=DWQ-2017-000801

DWQ onsite program page: “Professional List ... Maintenance Specialists List of Level 2 and/or Level 3 professionals who can be called to perform annual inspections for large underground system operating permits.” source

Effective date
2023-06-29

Systems in service

YearWhatLowMidHighMethod
1990All systems65,40365,40365,4031990 censussource
2021All systems174,909198,702221,769USGS estimate (2025)source

Pumps and aerators

Estimated systems in Utah with an aerobic treatment unit (aerator), an effluent or dosing pump, or either. How these are estimated

With an aerator
4,000
880 to 11,000 · 2% of all systems
With a pump
22,000
9,300 to 51,000 · 11% of all systems
Pump or aerator
24,000
9,600 to 55,000 · 12% of all systems

Control panels: about 24,000 installed (8,200 to 61,000), about 240 new a year and 1,600 replacements a year. How panels are estimated

AssumptionNo state figure was found; a regional assumption with a wide range.

No count found. West prior: mostly gravity; alternative systems in county programs (WA counties 2-7% aerobic).

Licensed professionals

No roster parsed yet. The state's list: https://lf-public.deq.utah.gov/WebLink/ElectronicFile.aspx?docid=454949&eqdocs=DWQ-2017-000801

Sources

Model catalog of installed septic hardware, and septic rules, permitting authorities and licensed providers by state and county. Every fact links to its source. Manufacturer photos are linked, not copied.