Franklin County
- Type
- County
- Area served
- entire County
- Address
- 208 HWY 37 S MOUNT VERNON , TX, 75457
- Phone
- (903) 537-4539
- Contacts
- Max Cannaday, Septic Inspector & Designated Representative, mcannaday@co.franklin.tx.us, (903) 537-8346; Jennifer Cooper, Administrative Assistant; 204 Texas Hwy 37, Mount Vernon TX 75457
- Counties
- Franklin County
Office hours: M-F 8am-12pm, 1-4pm Mailing: PO BOX 1106 MOUNT VERNON, TX, 75457 - 1106 atu_permits = Surface Irr. (spray) + Drip Irr. installs from TCEQ ATCS report (proxy: report has no treatment-type column); conventional = Standard trench/bed + Gravel-less + Leaching chamber + EZflow; total = ATC column.; Surface application systems on ≤1 acre usable area must spray between midnight and 5 a.m. (timer); 1-acre minimum lots for new subdivisions.
Local rules
- Administering body
- Franklin County
- Maintenance contract for aerobic or advanced units
- Yes, initial period only
- Initial contract (years)
- 2
- Homeowner self-maintenance
- Allowed after a course
- Self-maintenance conditions
- yes, conditional – homeowner who is at least a registered maintenance technician or passes a county-approved basic homeowner maintenance course; still subject to 285.91(12) testing/reporting; failing to submit reports for 10 consecutive months requires a licensed-provider contract within 30 days of notice
- Reports go to the authority
- Yes
- Report channel
- Not stated
- Electronic monitoring in the rule
- Alarm requirement only
- Monitoring wording
- Permit pack: aerobic spray systems need audible & visual alarm and separate circuit breaker for pumps and alarms; service-policy template voids warranty if the alarm is disconnected. Order justification: county must be able to 'track and monitor' OSSFs
- Fees and periodic programs
- none published; permit $375 residential / $550 commercial (2024 increase)
Permits issued by this authority
| Year | New | Aerobic (spray, drip, ATU) |
|---|---|---|
| 2025 | 85 | 77 |
| 2024 | 81 | 70 |
| 2023 | 105 | 98 |
| 2022 | 108 | 94 |
| 2021 | 101 | 96 |
| 2020 | 80 | 76 |
| 2019 | 52 | 47 |
| 2018 | 39 | 37 |
| 2017 | 65 | 53 |
| 2016 | 40 | 32 |
| 2015 | 50 | 42 |
New permits by pump and aerator
From the dispersal type on each permit in Franklin County (TCEQ install reports). Spray and drip need a pump and, in practice, an aerobic unit; low-pressure dosing, pumped effluent and mounds have a pump without an aerator. An aerobic unit discharging to gravity trenches is counted as gravity.
| Year | Pump and aerator (spray, drip) | Pump only (LPD, mound) | Gravity | Other | With a pump |
|---|---|---|---|---|---|
| 2025 | 77 | 1 | 3 | 4 | 92% |
| 2024 | 70 | 1 | 9 | 1 | 88% |
| 2023 | 98 | 2 | 5 | 0 | 95% |
| 2022 | 94 | 0 | 10 | 4 | 87% |
| 2021 | 96 | 0 | 4 | 1 | 95% |
| 2020 | 76 | 1 | 3 | 0 | 96% |
| 2019 | 47 | 1 | 3 | 1 | 92% |
| 2018 | 37 | 0 | 1 | 1 | 95% |
| 2017 | 53 | 0 | 11 | 1 | 82% |
| 2016 | 32 | 0 | 3 | 5 | 80% |
| 2015 | 42 | 0 | 1 | 7 | 84% |