Franklin County, Texas
Who permits septic systems here
County
- 208 HWY 37 S MOUNT VERNON , TX, 75457
- Phone: (903) 537-4539
- Email: mcannaday@co.franklin.tx.us
- Website
Local rules
These add to the state rule on the Texas page.
- Administering body
- Franklin County
- Maintenance contract for aerobic or advanced units
- Yes, initial period only
- Initial contract (years)
- 2
- Homeowner self-maintenance
- Allowed after a course
- Self-maintenance conditions
- yes, conditional – homeowner who is at least a registered maintenance technician or passes a county-approved basic homeowner maintenance course; still subject to 285.91(12) testing/reporting; failing to submit reports for 10 consecutive months requires a licensed-provider contract within 30 days of notice
- Reports go to the authority
- Yes
- Report channel
- Not stated
- Electronic monitoring in the rule
- Alarm requirement only
- Monitoring wording
- Permit pack: aerobic spray systems need audible & visual alarm and separate circuit breaker for pumps and alarms; service-policy template voids warranty if the alarm is disconnected. Order justification: county must be able to 'track and monitor' OSSFs
- Fees and periodic programs
- none published; permit $375 residential / $550 commercial (2024 increase)
Systems in service (estimates)
| Year | What | Low | Mid | High | Method | |
|---|---|---|---|---|---|---|
| 2021 | All systems | 4,890 | 4,890 | 4,890 | USGS estimate (2025) | source |
| 2025 | Aerobic (spray + drip permits) | 1,008 | 1,204 | 1,432 | Permit back-cast | source |
Pumps and aerators
Estimated systems in Franklin County with an aerobic treatment unit (aerator), an effluent or dosing pump, or either. How these are estimated
- With an aerator
- 1,500
- 1,000 to 1,700 · 30% of all systems
- With a pump
- 1,500
- 1,000 to 1,800 · 31% of all systems
- Pump or aerator
- 1,500
- 1,000 to 1,800 · 31% of all systems
CountedAn official count or peer-reviewed estimate of aerobic units exists for this state.
Texas: aerators follow the county's spray+drip permit back-cast; pump-only follows the county's own low-pressure/mound permit share; state basis counted
- Texas OSSF census back-cast (texas-ossf/scripts/estimate_aerobic_base.py) · med confidence
- Texas A&M AgriLife Extension, Onsite Wastewater Treatment and Reuse (program page) · med confidence
- TCEQ Types of Systems Installed 2025 · high confidence
New permits by pump and aerator
From the dispersal type on each permit in Franklin County (TCEQ install reports). Spray and drip need a pump and, in practice, an aerobic unit; low-pressure dosing, pumped effluent and mounds have a pump without an aerator. An aerobic unit discharging to gravity trenches is counted as gravity.
| Year | Pump and aerator (spray, drip) | Pump only (LPD, mound) | Gravity | Other | With a pump |
|---|---|---|---|---|---|
| 2025 | 77 | 1 | 3 | 4 | 92% |
| 2024 | 70 | 1 | 9 | 1 | 88% |
| 2023 | 98 | 2 | 5 | 0 | 95% |
| 2022 | 94 | 0 | 10 | 4 | 87% |
| 2021 | 96 | 0 | 4 | 1 | 95% |
| 2020 | 76 | 1 | 3 | 0 | 96% |
| 2019 | 47 | 1 | 3 | 1 | 92% |
| 2018 | 37 | 0 | 1 | 1 | 95% |
| 2017 | 53 | 0 | 11 | 1 | 82% |
| 2016 | 32 | 0 | 3 | 5 | 80% |
| 2015 | 42 | 0 | 1 | 7 | 84% |
Permits issued
| Year | New | Aerobic (spray, drip, ATU) |
|---|---|---|
| 2025 | 85 | 77 |
| 2024 | 81 | 70 |
| 2023 | 105 | 98 |
| 2022 | 108 | 94 |
| 2021 | 101 | 96 |
| 2020 | 80 | 76 |
| 2019 | 52 | 47 |
| 2018 | 39 | 37 |
| 2017 | 65 | 53 |
| 2016 | 40 | 32 |
| 2015 | 50 | 42 |
Septic companies serving Franklin County (2)
| Company | City | Services | Phone | Website |
|---|---|---|---|---|
| McNutt Site Services | Pittsburg | install, maintenance, pumping | site | |
| The Septic Company | Mt. Vernon | install, pumping | 9033657300 |
Licensed professionals based in Franklin County (14)
| Name | License | Number | City | Phone |
|---|---|---|---|---|
| MATHEWS, ROBERT | OSSF Apprentice | OS0039899 | ||
| MCBRIDE, TOM MATTISON | OSSF Apprentice | OS0039505 | ||
| CANNADAY, MERWYN MAX | Designated Representative | OS0039180 | ||
| CARR, BRANTIN DAYNE | Designated Representative | OS0008722 | ||
| RICKS, RODNEY C | Installer II | OS0004919 | ||
| ROSE, CHARLES R | Installer II | OS0000427 | ||
| SMELLEY, RONNIE R | Installer II | OS0003788 | ||
| TRANTHAM, JIMMY WAYNE SR | Installer II | OS0008168 | ||
| RICKS, RODNEY C | Maintenance Provider | MP0000757 | ||
| TRANTHAM, JIMMY WAYNE SR | Maintenance Provider | MP0000654 | ||
| FORD SEPTIC | Sludge transporter registration (TCEQ Central Registry, program SLUDGE) | 26548 | Winnsboro | |
| FRANKLIN COUNTY WATER DISTRICT | Sludge transporter registration (TCEQ Central Registry, program SLUDGE) | 23148 | Mount Vernon | |
| JONES SEPTIC SERVICES | Sludge transporter registration (TCEQ Central Registry, program SLUDGE) | 25611 | Winnsboro | |
| SMELLEY, RONNIE R | Site Evaluator | OS0012111 |
Rosters: https://www2.tceq.texas.gov/lic_dpa/index.cfm?fuseaction=licall.searchgp (OSSFOL/APP/region 5)https://www2.tceq.texas.gov/lic_dpa/index.cfm?fuseaction=licall.searchgp (OSSFOL/DR/region 5)https://www2.tceq.texas.gov/lic_dpa/index.cfm?fuseaction=licall.searchgp (OSSFOL/OSII/region 5)https://www2.tceq.texas.gov/lic_dpa/index.cfm?fuseaction=licall.searchgp (OSSFOL/OSMP/region 5)https://www15.tceq.texas.gov/crpub/index.cfm?fuseaction=regent.showSingleRN&re_id=636410392024114https://www15.tceq.texas.gov/crpub/index.cfm?fuseaction=regent.showSingleRN&re_id=427328742003153https://www15.tceq.texas.gov/crpub/index.cfm?fuseaction=regent.showSingleRN&re_id=375338452019064https://www2.tceq.texas.gov/lic_dpa/index.cfm?fuseaction=licall.searchgp (OSSFOL/SE/region 5)