Wyoming septic rules
Wyoming Department of Environmental Quality, Water Quality Division (WQD), Water and Wastewater Program · Small Wastewater Systems (septic) permitting. Statute: W.S. 35-11-101 et seq. (35-11-103(c)(ix) small wastewater facility; 35-11-301(a)(iii); 35-11-302(a)(iii); 35-11-304 delegation). Rule: Wyoming Water Quality Rules and Regulations, Chapter 25: Septic Tanks, Soil Absorption Systems, and Other Small Wastewater Systems.
For homeowners in Wyoming
- Depending on the county, either the state agency or a local agency permits septic systems. Find yours in the county list below.
- The state rule is silent on maintenance contracts for aerobic units.
Counties
The office that permits septic systems in each county, with the estimated number of systems and how many have an aerator or a pump. ● marks counties whose pump and aerator figures come from county records; the rest spread the state estimate.
What the state rule requires
- Administering body
- DEQ/WQD issues permits to construct for small wastewater facilities only in Campbell (commercial systems only), Carbon, Niobrara, Platte and Weston Counties; elsewhere delegated county small wastewater programs (county health departments or planning offices delegated under W.S. 35-11-304) permit, inspect and enforce under Chapter 25 minimum standards and their own county rules
DEQ small wastewater systems page; Chapter 25 Section 4(j): “DEQ authorizes permits to construct for small wastewater facilities, defined by Wyoming Statutes 35-11-103(c)(ix), that are located in Campbell (commercial systems only), Carbon, Niobrara, Platte, and Weston Counties where DEQ is the permitting authority. The permitting authority for other jurisdictions may require different forms or additional information. ... 'Delegated small wastewater program' means a local governmental entity, delegated by the Administrator, with the authority to administer the provisions of W.S. 35-11-301(a)(iii) for small wastewater systems pursuant to the provisions of W.S. 35-11-304.” source
- Administration model
- Mixed: state offices and local agencies
- Statute
- W.S. 35-11-302(a)(iii); 35-11-304
Chapter 25 Section 1: “This rule is promulgated pursuant to Wyoming Statutes (W.S.) 35-11-101 through 35-11-1904, specifically 35-11-302(a)(iii). ... minimum standards for the design and construction of small wastewater systems that are defined by W.S. 35-11-103(c)(ix).” source
- Rule
- WQD Rules Chapter 25
- License required
- No
Chapter 25 (full text search for 'licens'): “The only 'licensed' reference is to a licensed facility receiving septage; Chapter 25 sets design/construction standards and contains no installer, pumper or maintenance-provider licensing. County programs may license locally.” source
- Maintenance contract for aerobic or advanced units
- Not stated
Chapter 25 Section 18: “Septic tanks shall be pumped as needed to prevent solids carryover into the soil absorption system. ... Any service provider that pumps septic tanks, holding tanks, or sealed vaults, shall dispose of the wastewater contents at a permitted wastewater treatment facility or in a manner approved by the Division or delegated authority.” source
- Homeowner self-maintenance
- Not stated
- Electronic monitoring in the rule
- Alarm requirement only
Chapter 25 (pump chamber requirements): “High water alarms shall be provided for all tanks that use pumps or siphons. The alarm device shall be an audible alarm or an indoor illuminated alarm or both. ... Dosed systems using a siphon shall have a dose counter installed.” source
- Monitoring wording
- Chapter 25: High water alarms shall be provided for all tanks that use pumps or siphons. The alarm device shall be an audible alarm or an indoor illuminated alarm or both. Dosed systems using a siphon shall have a dose counter. No telemetry, remote monitoring or treatment-unit maintenance provision in the chapter.
- Alarm required
- Yes
Systems in service
| Year | What | Low | Mid | High | Method | |
|---|---|---|---|---|---|---|
| 1990 | All systems | 49,055 | 49,055 | 49,055 | 1990 census | source |
| 2021 | All systems | 127,089 | 133,212 | 138,681 | USGS estimate (2025) | source |
Pumps and aerators
Estimated systems in Wyoming with an aerobic treatment unit (aerator), an effluent or dosing pump, or either. How these are estimated
- With an aerator
- 2,700
- 640 to 6,900 · 2% of all systems
- With a pump
- 15,000
- 6,700 to 32,000 · 11% of all systems
- Pump or aerator
- 16,000
- 7,000 to 35,000 · 12% of all systems
Control panels: about 16,000 installed (5,900 to 38,000), about 160 new a year and 1,100 replacements a year. How panels are estimated
AssumptionNo state figure was found; a regional assumption with a wide range.
No count found. West prior: mostly gravity; alternative systems in county programs (WA counties 2-7% aerobic).
Licensed professionals
No roster parsed yet.
Sources
- WQD permit archive spreadsheets (1960-2016 and 2000-2021) linked from the Water & Wastewater page · Wyoming DEQ WQD, xlsx
- Small Wastewater Permitting Authority (by DEQ district and county) · Wyoming DEQ WQD, pdf
- DEQ Small Wastewater Systems permitting page (jurisdiction, forms, district engineers) · Wyoming DEQ WQD, html
- Laramie County septic system installers 2026 · Cheyenne Laramie County Public Health, pdf
- Natrona County 2026 installers list · Casper-Natrona County Health Department, pdf
- City of Casper sewer map with current septic permits · City of Casper / Casper-Natrona County Health Department, ArcGIS app
- Water Quality Rules Chapter 25 Septic Tanks, Soil Absorption Systems, and Other Small Wastewater Systems · Wyoming DEQ / Secretary of State rules portal, pdf