Wyoming septic rules

Wyoming Department of Environmental Quality, Water Quality Division (WQD), Water and Wastewater Program · Small Wastewater Systems (septic) permitting. Statute: W.S. 35-11-101 et seq. (35-11-103(c)(ix) small wastewater facility; 35-11-301(a)(iii); 35-11-302(a)(iii); 35-11-304 delegation). Rule: Wyoming Water Quality Rules and Regulations, Chapter 25: Septic Tanks, Soil Absorption Systems, and Other Small Wastewater Systems.

For homeowners in Wyoming

  • Depending on the county, either the state agency or a local agency permits septic systems. Find yours in the county list below.
  • The state rule is silent on maintenance contracts for aerobic units.

Counties

The office that permits septic systems in each county, with the estimated number of systems and how many have an aerator or a pump. ● marks counties whose pump and aerator figures come from county records; the rest spread the state estimate.

CountyPermitting authorityPhoneSystems (USGS mid)With an aeratorPump or aeratorLocal rules
Albany CountyAlbany County Planning Department307-721-25684,976100597
Big Horn CountyBig Horn County Land Planning Department307-568-24244,96499596
Campbell CountyCampbell County small wastewater (septic) program307-687-62009,2681851,112
Carbon CountyWyoming DEQ Water Quality Division, Water and Wastewater Program (district engineers)1-307-777-79375,935119712
Converse CountyConverse County Special Projects Department307-358-19905,418108650
Crook CountyCrook County Growth & Development (Planning)307-283-45483,96779476
Fremont CountyFremont County Planning Department, Small Wastewater program11,3352271,360
Goshen CountyGoshen County Planning Department (small wastewater)307-532-38525,424108651
Hot Springs CountyHot Springs County Planning Office307-864-29611,20024144
Johnson CountyJohnson County Planning Department307-684-19074,36087523
Laramie CountyCheyenne Laramie County Public Health, Environmental Health Division307.633.409010,4012081,248Yes
Lincoln CountyLincoln County Office of Planning & Development(307) 877-9056 (Kemmerer); (307) 885-3106 (Afton)8,5531711,026
Natrona CountyCasper-Natrona County Health Department, Wastewater-Septic Program307-235-93409,2961861,116
Niobrara CountyWyoming DEQ Water Quality Division, Water and Wastewater Program (district engineers)1-307-777-79371,68934203
Park CountyPark County Planning and Zoning Department, Small Wastewater(307) 527-8540 (Cody); (307) 754-8540 (Powell)7,153143858
Platte CountyWyoming DEQ Water Quality Division, Water and Wastewater Program (district engineers)1-307-777-79374,02781483
Sheridan CountySheridan County Public Works Department307-675-24205,825117699
Sublette CountySublette County Planning and Zoning307-367-43755,178104621
Sweetwater CountySweetwater County Environmental Health Department (District Board of Health)(307) 872-39306,234125748
Teton CountyTeton County Public Works, Engineering & Permitting Services (Building Division) - Small Wastewater Facilities6,965139836
Uinta CountyUinta County Planning & Development307-783-03015,060101607
Washakie CountyWashakie County Planning Office307-347-67782,27245273
Weston CountyWyoming DEQ Water Quality Division, Water and Wastewater Program (district engineers)1-307-777-79373,71274445

What the state rule requires

Administering body
DEQ/WQD issues permits to construct for small wastewater facilities only in Campbell (commercial systems only), Carbon, Niobrara, Platte and Weston Counties; elsewhere delegated county small wastewater programs (county health departments or planning offices delegated under W.S. 35-11-304) permit, inspect and enforce under Chapter 25 minimum standards and their own county rules

DEQ small wastewater systems page; Chapter 25 Section 4(j): “DEQ authorizes permits to construct for small wastewater facilities, defined by Wyoming Statutes 35-11-103(c)(ix), that are located in Campbell (commercial systems only), Carbon, Niobrara, Platte, and Weston Counties where DEQ is the permitting authority. The permitting authority for other jurisdictions may require different forms or additional information. ... 'Delegated small wastewater program' means a local governmental entity, delegated by the Administrator, with the authority to administer the provisions of W.S. 35-11-301(a)(iii) for small wastewater systems pursuant to the provisions of W.S. 35-11-304.” source

Administration model
Mixed: state offices and local agencies
Statute
W.S. 35-11-302(a)(iii); 35-11-304

Chapter 25 Section 1: “This rule is promulgated pursuant to Wyoming Statutes (W.S.) 35-11-101 through 35-11-1904, specifically 35-11-302(a)(iii). ... minimum standards for the design and construction of small wastewater systems that are defined by W.S. 35-11-103(c)(ix).” source

Rule
WQD Rules Chapter 25
License required
No

Chapter 25 (full text search for 'licens'): “The only 'licensed' reference is to a licensed facility receiving septage; Chapter 25 sets design/construction standards and contains no installer, pumper or maintenance-provider licensing. County programs may license locally.” source

Maintenance contract for aerobic or advanced units
Not stated

Chapter 25 Section 18: “Septic tanks shall be pumped as needed to prevent solids carryover into the soil absorption system. ... Any service provider that pumps septic tanks, holding tanks, or sealed vaults, shall dispose of the wastewater contents at a permitted wastewater treatment facility or in a manner approved by the Division or delegated authority.” source

Homeowner self-maintenance
Not stated
Electronic monitoring in the rule
Alarm requirement only

Chapter 25 (pump chamber requirements): “High water alarms shall be provided for all tanks that use pumps or siphons. The alarm device shall be an audible alarm or an indoor illuminated alarm or both. ... Dosed systems using a siphon shall have a dose counter installed.” source

Monitoring wording
Chapter 25: High water alarms shall be provided for all tanks that use pumps or siphons. The alarm device shall be an audible alarm or an indoor illuminated alarm or both. Dosed systems using a siphon shall have a dose counter. No telemetry, remote monitoring or treatment-unit maintenance provision in the chapter.
Alarm required
Yes

Systems in service

YearWhatLowMidHighMethod
1990All systems49,05549,05549,0551990 censussource
2021All systems127,089133,212138,681USGS estimate (2025)source

Pumps and aerators

Estimated systems in Wyoming with an aerobic treatment unit (aerator), an effluent or dosing pump, or either. How these are estimated

With an aerator
2,700
640 to 6,900 · 2% of all systems
With a pump
15,000
6,700 to 32,000 · 11% of all systems
Pump or aerator
16,000
7,000 to 35,000 · 12% of all systems

Control panels: about 16,000 installed (5,900 to 38,000), about 160 new a year and 1,100 replacements a year. How panels are estimated

AssumptionNo state figure was found; a regional assumption with a wide range.

No count found. West prior: mostly gravity; alternative systems in county programs (WA counties 2-7% aerobic).

Licensed professionals

No roster parsed yet.

Sources

Model catalog of installed septic hardware, and septic rules, permitting authorities and licensed providers by state and county. Every fact links to its source. Manufacturer photos are linked, not copied.