Robertson County
- Type
- County
- Area served
- entire County except Lake Limestone Regulated Area (see Brazos River Authority)
- Address
- 102 W Decherd St FRANKLIN , TX, 77856
- Phone
- (979) 828-6684
- Contacts
- Charles Palcer (OSSF Designated Representative), PO Box 427, Franklin TX 77856; robco.drep@co.robertson.tx.us; 979-828-6684
- Counties
- Robertson County (partial)
Office hours: M-F 8am-5pm Mailing: PO BOX 427 FRANKLIN, TX, 77856 - 0427 atu_permits = Surface Irr. (spray) + Drip Irr. installs from TCEQ ATCS report (proxy: report has no treatment-type column); conventional = Standard trench/bed + Gravel-less + Leaching chamber + EZflow; total = ATC column.; New order effective 2025-09-01 with explicit justifications.
Local rules
- Administering body
- Robertson County
- Maintenance contract for aerobic or advanced units
- Yes (term not stated)
- Homeowner self-maintenance
- Allowed after a course
- Self-maintenance conditions
- yes, conditional – homeowner who completes TEEX #WWW301, AgriLife #AGEN-CO-003 or another county-approved aerobic maintenance class and submits the certificate; must meet 285.91(12) testing/reporting; failing to submit reports for eight consecutive months forfeits homeowner maintenance
- Reports go to the authority
- Yes
- Report channel
- Not stated
- Electronic monitoring in the rule
- None found
- Monitoring wording
- Order justification: county must be able to 'track and monitor the general health' of OSSFs through contracted maintenance (no device/remote-monitoring rule)
- Fees and periodic programs
- none published; permit $300 residential / $500 commercial from 2025-09-01
Permits issued by this authority
| Year | New | Aerobic (spray, drip, ATU) |
|---|---|---|
| 2025 | 133 | 99 |
| 2024 | 114 | 81 |
| 2023 | 110 | 81 |
| 2022 | 101 | 63 |
| 2021 | 83 | 49 |
| 2020 | 113 | 90 |
| 2019 | 68 | 41 |
| 2018 | 71 | 31 |
| 2017 | 72 | 39 |
| 2016 | 73 | 36 |
| 2015 | 58 | 23 |
New permits by pump and aerator
From the dispersal type on each permit in Robertson County (TCEQ install reports). Spray and drip need a pump and, in practice, an aerobic unit; low-pressure dosing, pumped effluent and mounds have a pump without an aerator. An aerobic unit discharging to gravity trenches is counted as gravity.
| Year | Pump and aerator (spray, drip) | Pump only (LPD, mound) | Gravity | Other | With a pump |
|---|---|---|---|---|---|
| 2025 | 99 | 1 | 33 | 0 | 75% |
| 2024 | 81 | 0 | 33 | 0 | 71% |
| 2023 | 81 | 2 | 27 | 0 | 75% |
| 2022 | 63 | 3 | 35 | 0 | 65% |
| 2021 | 49 | 2 | 32 | 0 | 61% |
| 2020 | 90 | 0 | 23 | 0 | 80% |
| 2019 | 41 | 0 | 26 | 1 | 60% |
| 2018 | 31 | 1 | 39 | 0 | 45% |
| 2017 | 39 | 2 | 31 | 0 | 57% |
| 2016 | 36 | 0 | 32 | 5 | 49% |
| 2015 | 23 | 1 | 33 | 1 | 41% |