Walker County
- Type
- County
- Area served
- unincorporated County
- Address
- 1313 University Ave, Huntsville, TX 77320
- Phone
- (936) 436-4939
- Contacts
- Andrew Isbell – OARS primary contact – AISBELL@CO.WALKER.TX.US – (936) 436-4953
- Counties
- Walker County (partial)
Office hours: M-F 8am-12pm, 1-5pm Mailing: 1301 SAM HOUSTON AVE STE 113 HUNTSVILLE, TX, 77340 - 4500 Reports must include unauthorized alterations, spray area condition, permit no., license ID, provider emergency phone. One BOD/TSS grab sample per year for food establishments. atu_permits = Surface Irr. (spray) + Drip Irr. installs from TCEQ ATCS report (proxy: report has no treatment-type column); conventional = Standard trench/bed + Gravel-less + Leaching chamber + EZflow; total = ATC column.
Local rules
- Administering body
- Walker County
- Maintenance contract for aerobic or advanced units
- Yes (term not stated)
- Homeowner self-maintenance
- Allowed after a course
- Self-maintenance conditions
- Only if single-family primary residence, disposal area ≥50 ft from property line, AND owner is a registered MP for their ATU, or was trained per HB 2510, or holds Class D+ wastewater license, or completed TCEQ basic MP course, TEEX aerobic/surface O&M course, or AgriLife B-6235 course; self-maintainers must still submit all reports/tests plus fees
- Reports go to the authority
- Yes
- Report channel
- Not stated
- Electronic monitoring in the rule
- Alarm requirement only
- Monitoring wording
- Where a visual and audible alarm is required for an OSSF serving a Food Establishment, an additional visual/audible alarm must be inside the facility in view of employees/management; food establishments with secondary treatment checked monthly
- Fees and periodic programs
- Order references report/contract fees (owner fees may differ from provider fees); amount not found. H-GAC 2012 summary notes Walker County adopted an administrative fee for reviewing each maintenance report
Permits issued by this authority
| Year | New | Aerobic (spray, drip, ATU) |
|---|---|---|
| 2025 | 284 | 277 |
| 2024 | 281 | 275 |
| 2023 | 334 | 331 |
| 2022 | 478 | 470 |
| 2021 | 421 | 411 |
| 2020 | 333 | 320 |
| 2019 | 320 | 309 |
| 2018 | 268 | 262 |
| 2017 | 244 | 236 |
| 2016 | 235 | 221 |
| 2015 | 199 | 174 |
New permits by pump and aerator
From the dispersal type on each permit in Walker County (TCEQ install reports). Spray and drip need a pump and, in practice, an aerobic unit; low-pressure dosing, pumped effluent and mounds have a pump without an aerator. An aerobic unit discharging to gravity trenches is counted as gravity.
| Year | Pump and aerator (spray, drip) | Pump only (LPD, mound) | Gravity | Other | With a pump |
|---|---|---|---|---|---|
| 2025 | 277 | 0 | 7 | 0 | 98% |
| 2024 | 275 | 0 | 6 | 0 | 98% |
| 2023 | 331 | 0 | 3 | 0 | 99% |
| 2022 | 470 | 0 | 7 | 1 | 98% |
| 2021 | 411 | 0 | 10 | 0 | 98% |
| 2020 | 320 | 0 | 12 | 1 | 96% |
| 2019 | 309 | 0 | 10 | 1 | 97% |
| 2018 | 262 | 1 | 5 | 0 | 98% |
| 2017 | 236 | 2 | 6 | 0 | 98% |
| 2016 | 221 | 0 | 14 | 0 | 94% |
| 2015 | 174 | 0 | 25 | 0 | 87% |