Tarrant County
- Type
- County
- Area served
- unincorporated area + Azle,Bedford,Benbrook,Colleyville,Crowley,Forest Hill,Grapevine,Haltom City,Haslet,Hurst,Keller,Kennedale,Lakeside,Mansfield,North Richland Hills,Richland Hills,Southlake,Watauga,Westlake,Westover Hills,Westworth Village
- Address
- 200 Taylor St #305, Fort Worth, TX 76196 (OARS)
- Phone
- 817-212-7082
- Contacts
- Ekpen Okoruwa – Wastewater Specialist – EOOkoruwa@tarrantcountytx.gov – 817-212-7082; Maria Moreno – Environmental Specialist – MCMoreno2@tarrantcountytx.gov – 817-884-2634
- Counties
- Tarrant County (partial)
Office hours: M-F 8am-5pm Mailing: 200 TAYLOR ST STE 305 FORT WORTH, TX, 76196 - 0206 Court Order 146317 (adopted Nov 11, 2025) requires lots of at least one acre in new single-family subdivisions Area served: unincorporated county + many cities (Azle, Bedford, Benbrook, Colleyville, Crowley, Grapevine, Keller, Mansfield, etc.). New aerobic permits require recorded OSSF affidavit. Posted "OSSF Rules and Regulations" PDF is a copy of 30 TAC 285 Subchapter D. atu_permits = Surface Irr. (spray) + Drip Irr. installs from TCEQ ATCS report (proxy: report has no treatment-type column); conventional = Standard trench/bed + Gravel-less + Leaching chamber + EZflow; total = ATC column.
Local rules
- Administering body
- Tarrant County
- Maintenance contract for aerobic or advanced units
- Yes (term not stated)
- Fees and periodic programs
- No annual fee published. Permit: residential $277 any system; non-residential $277 conventional / $285 aerobic; repair/remodel $117; re-inspection $92
Permits issued by this authority
| Year | New | Aerobic (spray, drip, ATU) |
|---|---|---|
| 2025 | 273 | 204 |
| 2024 | 363 | 220 |
| 2023 | 335 | 250 |
| 2022 | 402 | 308 |
| 2021 | 349 | 303 |
| 2020 | 370 | 313 |
| 2019 | 366 | 311 |
| 2018 | 347 | 273 |
| 2017 | 369 | 303 |
| 2016 | 380 | 338 |
| 2015 | 349 | 312 |
New permits by pump and aerator
From the dispersal type on each permit in Tarrant County (TCEQ install reports). Spray and drip need a pump and, in practice, an aerobic unit; low-pressure dosing, pumped effluent and mounds have a pump without an aerator. An aerobic unit discharging to gravity trenches is counted as gravity.
| Year | Pump and aerator (spray, drip) | Pump only (LPD, mound) | Gravity | Other | With a pump |
|---|---|---|---|---|---|
| 2025 | 204 | 39 | 25 | 5 | 89% |
| 2024 | 220 | 61 | 24 | 0 | 92% |
| 2023 | 250 | 27 | 25 | 1 | 91% |
| 2022 | 308 | 1 | 50 | 3 | 85% |
| 2021 | 303 | 4 | 37 | 5 | 88% |
| 2020 | 313 | 5 | 52 | 0 | 86% |
| 2019 | 311 | 6 | 49 | 0 | 87% |
| 2018 | 273 | 26 | 48 | 0 | 86% |
| 2017 | 303 | 12 | 54 | 0 | 85% |
| 2016 | 338 | 8 | 33 | 1 | 91% |
| 2015 | 312 | 5 | 30 | 2 | 91% |