Jefferson County
- Type
- County
- Area served
- unincorporated County
- Address
- Jefferson County Environmental Control, 7933 Viterbo Road Ste 4, Beaumont, TX 77705
- Phone
- (409) 719-5910
- Contacts
- Ronda Conlin – Environmental Control (OARS primary contact) – Ronda.Conlin@jeffersoncountytx.gov – (409) 719-5910; Heather Marshall-Dore – Environmental Control staff – Heather.Marshall@jeffersoncountytx.gov – (409) 719-5910; Christopher Peltier – Environmental Control staff – Christopher.Peltier@jeffersoncountytx.gov – (409) 719-5910; Angela Caraway – Environmental Control staff – Angela.Caraway@jeffersoncountytx.gov – (409) 719-5910; Bryanna Moore – Environmental Control staff – Bryanna.Moore@jeffersoncountytx.gov – (409) 719-5910
- Counties
- Jefferson County (partial)
Office hours: M-F 8am-12pm, 1-5pm Mailing: 7933 VITERBO RD STE 4 BEAUMONT, TX, 77705 - 9295 Permits required regardless of tract size. Failure to hold or renew contract can result in legal action against the owner. atu_permits = Surface Irr. (spray) + Drip Irr. installs from TCEQ ATCS report (proxy: report has no treatment-type column); conventional = Standard trench/bed + Gravel-less + Leaching chamber + EZflow; total = ATC column.
Local rules
- Administering body
- Jefferson County
- Maintenance contract for aerobic or advanced units
- Yes, for the life of the system
- Contract for the life of the system
- Yes
- Homeowner self-maintenance
- Allowed after a course
- Self-maintenance conditions
- only if the owner is a TCEQ registered maintenance provider for their ATU, was trained per HB 2510 (79R) before HB 2482 (80R), or holds a Class D or higher wastewater license and is manufacturer-certified for their brand (more stringent county rule)
- Service visits per year
- 3
- Reports go to the authority
- Yes
- Report channel
- Not stated
- Electronic monitoring in the rule
- None found
- Monitoring wording
- County order requires each testing report to include sludge levels in the pump tank and condition of the spray area; maintenance tag punched/marked each visit
Permits issued by this authority
| Year | New | Aerobic (spray, drip, ATU) |
|---|---|---|
| 2025 | 132 | 132 |
| 2024 | 118 | 118 |
| 2023 | 124 | 124 |
| 2022 | 171 | 169 |
| 2021 | 159 | 158 |
| 2020 | 150 | 144 |
| 2019 | 213 | 211 |
| 2018 | 180 | 164 |
| 2017 | 127 | 126 |
| 2016 | 127 | 110 |
| 2015 | 140 | 140 |
New permits by pump and aerator
From the dispersal type on each permit in Jefferson County (TCEQ install reports). Spray and drip need a pump and, in practice, an aerobic unit; low-pressure dosing, pumped effluent and mounds have a pump without an aerator. An aerobic unit discharging to gravity trenches is counted as gravity.
| Year | Pump and aerator (spray, drip) | Pump only (LPD, mound) | Gravity | Other | With a pump |
|---|---|---|---|---|---|
| 2025 | 132 | 0 | 0 | 0 | 100% |
| 2024 | 118 | 0 | 0 | 0 | 100% |
| 2023 | 124 | 0 | 0 | 0 | 100% |
| 2022 | 169 | 0 | 0 | 2 | 99% |
| 2021 | 158 | 0 | 0 | 1 | 99% |
| 2020 | 144 | 0 | 4 | 2 | 96% |
| 2019 | 211 | 0 | 0 | 2 | 99% |
| 2018 | 164 | 0 | 13 | 3 | 91% |
| 2017 | 126 | 0 | 0 | 1 | 99% |
| 2016 | 110 | 0 | 14 | 3 | 87% |
| 2015 | 140 | 0 | 0 | 0 | 100% |