Hunt County
- Type
- County
- Area served
- unincorporated County + Town of Poetry ONLY, except w/in 2,000 ft from Lake Tawakoni - see Sabine River Authority
- Address
- 2701 Johnson St, Greenville, TX 75401
- Phone
- (903) 408-4140
- Contacts
- Brittnay Cooper, D.R., R.S., S.E., C.P.O. (Environmental Officer); Joshua Richie, D.R., S.E., O.S. II, C.F.M. (Environmental Officer); health@huntcounty.net; (903) 408-4140; 2701 Johnson St, Greenville TX 75401
- Septic page
- https://www.huntcounty.net/page/hunt.septic
- Counties
- Hunt County (partial)
Office hours: M-F 8am-5pm Mailing: 2700 JOHNSON ST GREENVILLE, TX, 75401 - 4240 Publishes "Aerobic Wastewater Treatment Systems Homeowners Information" PDF (scanned, not parsed). Jurisdiction: unincorporated county + Town of Poetry, except within 2000 ft of Lake Tawakoni (SRA). atu_permits = Surface Irr. (spray) + Drip Irr. installs from TCEQ ATCS report (proxy: report has no treatment-type column); conventional = Standard trench/bed + Gravel-less + Leaching chamber + EZflow; total = ATC column.; Non-residential OSSF need annual BOD/TSS testing reported by provider. Hunt County states it does not require aerobic systems. Owner signs aerobic homeowner information sheet at permit.
Local rules
- Administering body
- Hunt County
- Maintenance contract for aerobic or advanced units
- Yes, for the life of the system
Order 9F.3; homeowner sheet source
- Contract for the life of the system
- Yes
- Homeowner self-maintenance
- Allowed after a course
Order 9F.4 source
- Self-maintenance conditions
- yes, conditional – after the initial 2-year policy a single-family owner may maintain personally after completing an approved OSSF maintenance training course; DR may inspect self-maintained systems any time (Order 9F.4)
- Service visits per year
- 3
- Reports go to the authority
- Yes
- Report channel
- Paper
- Electronic monitoring in the rule
- Alarm requirement only
- Monitoring wording
- Order lists alarms among non-buried components; reports must address sludge level in pump tank and spray area condition; no remote-monitoring language
- Annual operating permit
- Yes
- Annual fee (USD)
- 75
Order 9F.8 source
- Fees and periodic programs
- $75 aerobic annual registration (fee schedule eff. 2022-06-01); systems requiring maintenance must register annually (Order 9F.8); admin fee per renewed contract
Permits issued by this authority
| Year | New | Aerobic (spray, drip, ATU) |
|---|---|---|
| 2025 | 593 | 585 |
| 2024 | 645 | 637 |
| 2023 | 625 | 620 |
| 2022 | 798 | 784 |
| 2021 | 658 | 644 |
| 2020 | 570 | 553 |
| 2019 | 531 | 513 |
| 2018 | 545 | 517 |
| 2017 | 471 | 449 |
| 2016 | 426 | 392 |
| 2015 | 328 | 302 |
New permits by pump and aerator
From the dispersal type on each permit in Hunt County (TCEQ install reports). Spray and drip need a pump and, in practice, an aerobic unit; low-pressure dosing, pumped effluent and mounds have a pump without an aerator. An aerobic unit discharging to gravity trenches is counted as gravity.
| Year | Pump and aerator (spray, drip) | Pump only (LPD, mound) | Gravity | Other | With a pump |
|---|---|---|---|---|---|
| 2025 | 585 | 6 | 2 | 0 | 100% |
| 2024 | 637 | 8 | 0 | 0 | 100% |
| 2023 | 620 | 4 | 1 | 0 | 100% |
| 2022 | 784 | 12 | 2 | 0 | 100% |
| 2021 | 644 | 10 | 4 | 0 | 99% |
| 2020 | 553 | 13 | 4 | 0 | 99% |
| 2019 | 513 | 15 | 3 | 0 | 99% |
| 2018 | 517 | 23 | 4 | 1 | 99% |
| 2017 | 449 | 17 | 3 | 2 | 99% |
| 2016 | 392 | 24 | 10 | 0 | 98% |
| 2015 | 302 | 20 | 6 | 0 | 98% |