Grayson County
- Type
- County
- Area served
- entire County
- Address
- 100 W Houston St, Ste G-3, Sherman, TX 75090
- Phone
- (903) 813-4247
- Contacts
- Paula Shaw – OARS primary contact – PAULA.SHAW@CO.GRAYSON.TX.US – (903) 813-4247
- Permit platform
- MyGovernmentOnline / MyPermitNow (MGO)
- Septic page
- https://www.co.grayson.tx.us/page/dev.home
- Counties
- Grayson County
Office hours: M-F 8am-12pm, 1-5pm Mailing: 100 W HOUSTON ST STE G-3 SHERMAN, TX, 75090 - 5939 Order 07/07/2022: parcels with 4+ RVs must use aerobic treatment with no surface application. Jurisdiction: entire county. atu_permits = Surface Irr. (spray) + Drip Irr. installs from TCEQ ATCS report (proxy: report has no treatment-type column); conventional = Standard trench/bed + Gravel-less + Leaching chamber + EZflow; total = ATC column.
Local rules
- Administering body
- Grayson County
- Maintenance contract for aerobic or advanced units
- Yes (term not stated)
Order Sec. 10(H source
- Homeowner self-maintenance
- Allowed after a course
- Self-maintenance conditions
- yes, conditional – homeowner is licensed provider OR passes county-approved homeowner course, signs Homeowner Self-Maintenance Contract with county, meets all inspection/testing/reporting requirements; failure to submit reports within 14 days of scheduled dates revokes self-maintenance
- Service visits per year
- 3
- Reports go to the authority
- Yes
- Report channel
- Paper
- Report platform
- MyGovernmentOnline / MyPermitNow (MGO)
- Electronic monitoring in the rule
- None found
- Monitoring wording
- testing & reporting form checks aerators, filters, irrigation/recirculation pumps, disinfection, chlorine supply, electrical circuits; frequency every 4 months
Permits issued by this authority
| Year | New | Aerobic (spray, drip, ATU) |
|---|---|---|
| 2025 | 681 | 656 |
| 2024 | 774 | 743 |
| 2023 | 801 | 745 |
| 2022 | 873 | 799 |
| 2021 | 785 | 669 |
| 2020 | 676 | 559 |
| 2019 | 583 | 493 |
| 2018 | 556 | 431 |
| 2017 | 533 | 407 |
| 2016 | 465 | 344 |
| 2015 | 320 | 215 |
New permits by pump and aerator
From the dispersal type on each permit in Grayson County (TCEQ install reports). Spray and drip need a pump and, in practice, an aerobic unit; low-pressure dosing, pumped effluent and mounds have a pump without an aerator. An aerobic unit discharging to gravity trenches is counted as gravity.
| Year | Pump and aerator (spray, drip) | Pump only (LPD, mound) | Gravity | Other | With a pump |
|---|---|---|---|---|---|
| 2025 | 656 | 5 | 20 | 0 | 97% |
| 2024 | 743 | 4 | 27 | 0 | 97% |
| 2023 | 745 | 9 | 47 | 0 | 94% |
| 2022 | 799 | 7 | 67 | 0 | 92% |
| 2021 | 669 | 20 | 96 | 0 | 88% |
| 2020 | 559 | 13 | 104 | 0 | 85% |
| 2019 | 493 | 18 | 72 | 0 | 88% |
| 2018 | 431 | 20 | 105 | 0 | 81% |
| 2017 | 407 | 21 | 105 | 0 | 80% |
| 2016 | 344 | 15 | 106 | 0 | 77% |
| 2015 | 215 | 12 | 93 | 0 | 71% |