Fannin County

Type
County
Area served
unincorporated County + City of Bonham
Address
Fannin County Environmental Development, 1203 E. Sam Rayburn Drive, East Annex, Bonham, TX 75418
Phone
903-583-7495
Contacts
Lita Leatherwood – D.R. (designated representative) – septicpermits@fanninco.net – 903-583-7495
Permit platform
MGO Connect (MyGovernmentOnline)
Counties
Fannin County (partial)

Office hours: M-F 8am-5pm Mailing: 1203 E SAM RAYBURN DR BONHAM, TX, 75418 - 4945 Permits expire one year from ATC. TCEQ order PDF on site (1-26-09) is a scan. atu_permits = Surface Irr. (spray) + Drip Irr. installs from TCEQ ATCS report (proxy: report has no treatment-type column); conventional = Standard trench/bed + Gravel-less + Leaching chamber + EZflow; total = ATC column.

Local rules

Administering body
Fannin County
Maintenance contract for aerobic or advanced units
Yes, initial period only

source

Initial contract (years)
2
Homeowner self-maintenance
Allowed

source

Self-maintenance conditions
apparently yes – Testing and Reporting Record refers to "Maintenance Company or Approved Homeowner performing the inspection"
Service visits per year
3
Reports go to the authority
Yes
Report channel
Paper

source

Report platform
MGO Connect (MyGovernmentOnline)

source

Electronic monitoring in the rule
Alarm requirement only

source

Monitoring wording
Testing and Reporting Record includes inspected item "Alarm Light & Alarm"
Annual operating permit
Yes
Annual fee (USD)
550

source

Fees and periodic programs
Annual Contract Fee $25.00; Late Contract Fee $50.00 (checklist dated 05-18-2026). Permit: residential $375, commercial $550, repair $150, re-inspection $100, paper application $50, variance $1,500

Permits issued by this authority

YearNewAerobic (spray, drip, ATU)
2025269258
2024247240
2023335313
2022389340
2021305282
2020268247
2019271251
2018263217
2017292256
2016252203
2015185127

New permits by pump and aerator

From the dispersal type on each permit in Fannin County (TCEQ install reports). Spray and drip need a pump and, in practice, an aerobic unit; low-pressure dosing, pumped effluent and mounds have a pump without an aerator. An aerobic unit discharging to gravity trenches is counted as gravity.

YearPump and aerator (spray, drip)Pump only (LPD, mound)GravityOtherWith a pump
202525847097%
202424052099%
2023313220094%
202234079097%
2021282814195%
2020247912096%
2019251146098%
2018217244083%
2017256333089%
20162031039085%
2015127553071%

Model catalog of installed septic hardware, and septic rules, permitting authorities and licensed providers by state and county. Every fact links to its source. Manufacturer photos are linked, not copied.