City Of Lucas
- Type
- City
- Area served
- administered by Collin County
- Address
- 4690 Community Ave, Ste 200 McKinney, TX, 75071
- Phone
- (972) 548-5585
- Contacts
- City of Lucas Development Services (Director Joe Hilbourn in 2020 newsletter); Collin County Development Services 972-548-5585
- Counties
- Collin County (partial)
Office hours: M-F 8am-5pm Mailing: 825 N MCDONALD ST STE 170 MCKINNEY, TX, 75069 - 2175 atu_permits = Surface Irr. (spray) + Drip Irr. installs from TCEQ ATCS report (proxy: report has no treatment-type column); conventional = Standard trench/bed + Gravel-less + Leaching chamber + EZflow; total = ATC column.; City newsletters name Collin County Development Services as the Authorized Agent for Lucas residents, although TCEQ lists the City of Lucas as an AA (69 aerobic-proxy installs 2025) – relationship unclear. lucastexas.us pages return 403 (also in a browser); newsletters (June 2015, July 2020) downloaded and re-read on 2026-10-31.
Local rules
- Administering body
- City Of Lucas
- Maintenance contract for aerobic or advanced units
- Yes, initial period only
- Initial contract (years)
- 2
- Homeowner self-maintenance
- Allowed after the initial contract
- Self-maintenance conditions
- yes, conditional – City newsletter (June 2015): Texas law lets homeowners maintain their own system only after meeting specific, stringent requirements
- Service visits per year
- 3
- Reports go to the authority
- Yes
- Report channel
- Not stated
- Electronic monitoring in the rule
- Reduces required service visits
- Monitoring wording
- Remote-monitoring language: City newsletter (June 2015) says reports are due every 6 months instead of 4 'if the system uses an electronic monitor'; current 30 TAC 285.7(e)(3) lets required tests drop to two per year for systems with electronic monitoring and automatic telephone or radio notification of failures that also monitors disinfection
Permits issued by this authority
| Year | New | Aerobic (spray, drip, ATU) |
|---|---|---|
| 2025 | 77 | 69 |
| 2024 | 44 | 43 |
| 2023 | 0 | |
| 2022 | 0 | |
| 2021 | 0 | |
| 2020 | 0 | |
| 2019 | 0 | |
| 2018 | 0 |
New permits by pump and aerator
From the dispersal type on each permit in City Of Lucas (TCEQ install reports). Spray and drip need a pump and, in practice, an aerobic unit; low-pressure dosing, pumped effluent and mounds have a pump without an aerator. An aerobic unit discharging to gravity trenches is counted as gravity.
| Year | Pump and aerator (spray, drip) | Pump only (LPD, mound) | Gravity | Other | With a pump |
|---|---|---|---|---|---|
| 2025 | 69 | 8 | 0 | 0 | 100% |
| 2024 | 43 | 1 | 0 | 0 | 100% |