Bell County Public Health District

Type
Health district
Area served
entire County
Address
4236 Lowes Dr, Temple, TX 76502
Phone
(254) 532-9800
Contacts
Josh Langley – OARS primary contact – ossf@bellcountyhealth.org – (254) 532-9800
Counties
Bell County

Office hours: M-Th 8am-5:00pm, F 8-11:30am Mailing: 4236 LOWES DR TEMPLE, TX, 76502 - 3517 Installers delinquent in submitting maintenance reports are not issued authorization to construct. Jurisdiction: entire county. atu_permits = Surface Irr. (spray) + Drip Irr. installs from TCEQ ATCS report (proxy: report has no treatment-type column); conventional = Standard trench/bed + Gravel-less + Leaching chamber + EZflow; total = ATC column.

Local rules

Administering body
Bell County Public Health District
Maintenance contract for aerobic or advanced units
Yes (term not stated)

source

Homeowner self-maintenance
Allowed after a course

source

Self-maintenance conditions
yes, conditional – owner must reside in the single-family dwelling and complete BCPHD-approved coursework (only approved course: TOWA Maintenance Technician class); loses approval on confirmed nuisance or failure to submit
Reports go to the authority
Yes
Report channel
Not stated

source

Electronic monitoring in the rule
None found

source

Monitoring wording
food-dealer facilities: maintained every 3 months, chlorine/fecal test each visit, annual BOD/TSS, water meter reading with each report
Annual operating permit
Yes
Annual fee (USD)
20

source

Fees and periodic programs
$20 per contract year – "Maintenance Inspection / Contract Verification"; permit standard $610, professional design $710 (eff. Sept 1 2024)

Permits issued by this authority

YearNewAerobic (spray, drip, ATU)
2025681613
2024597531
2023639552
2022828756
2021702574
2020596469
2019576467
2018534419
2017496374
2016424313
2015311225

New permits by pump and aerator

From the dispersal type on each permit in Bell County Public Health District (TCEQ install reports). Spray and drip need a pump and, in practice, an aerobic unit; low-pressure dosing, pumped effluent and mounds have a pump without an aerator. An aerobic unit discharging to gravity trenches is counted as gravity.

YearPump and aerator (spray, drip)Pump only (LPD, mound)GravityOtherWith a pump
2025613860091%
2024531461190%
20235521271488%
2022756666092%
2021574164090%
20204691266188%
20194672186285%
20184191797182%
201737411104278%
20163131270681%
2015225669177%

Model catalog of installed septic hardware, and septic rules, permitting authorities and licensed providers by state and county. Every fact links to its source. Manufacturer photos are linked, not copied.