Rhode Island septic rules

Rhode Island Department of Environmental Management, Office of Water Resources, OWTS Program · Onsite Wastewater Treatment Systems (OWTS) Program. Statute: R.I. Gen. Laws 42-17.1; 5-56 (installers); 5-56.1 (designers); 23-19.5; 23-19.15 (Cesspool Act of 2007). Rule: 250-RICR-150-10-6 (OWTS Rules).

For homeowners in Rhode Island

  • Rhode Island Department of Environmental Management, Office of Water Resources, OWTS Program issues septic permits directly. Find yours in the county list below.
  • Aerobic and advanced treatment units must stay under a maintenance contract for as long as the system is in use.
  • No statewide septic inspection is required when a home is sold.

Counties

The office that permits septic systems in each county, with the estimated number of systems and how many have an aerator or a pump. ● marks counties whose pump and aerator figures come from county records; the rest spread the state estimate.

What the state rule requires

Administering body
RIDEM Office of Water Resources approves plans and permits every OWTS statewide; municipalities may not issue building permits until DEM approvals are presented (6.15(D)); DEM licenses designers, soil evaluators and installers and keeps the System Inspector list

250-RICR-150-10-6.9(C), 6.15(D): “No person shall install, alter, or repair an OWTS without the Director's written approval of the plans and specifications for such work; municipalities cannot issue building permits until required DEM approvals are presented.” source

Administration model
State agency permits directly
Statute
R.I. Gen. Laws 42-17.1; 5-56; 5-56.1; 23-19.5; 23-19.15
Rule
250-RICR-150-10-6
License required
Yes

250-RICR-150-10-6.2, 6.10, 6.14(A): “These Rules are promulgated pursuant to ... Chapter 5-56, Installers of Individual Sewage Disposal Systems; Chapter 5-56.1, Designers of Individual Sewage Disposal Systems. An Installer's License authorizes an individual to install, construct, alter or repair an OWTS.” source

License classes
designer;site_evaluator;installer;inspector_pos

250-RICR-150-10-6.10, 6.14, 6.8(80): “'System inspector' means a person on a DEM-approved list with the minimum qualifications of holding a Class I, II, or III Designers License or being a Registered System Inspector with the New England Onsite Wastewater Training Center. Class I/II/III Designer's Licenses, Class IV soil evaluator; licenses valid up to three years.” source

Maintenance contract for aerobic or advanced units
Yes, for the life of the system

250-RICR-150-10-6.55(A); 6.36(D)(1); 6.41(I): “Where required by an Alternative or Experimental Technology approval or under the terms of the approved OWTS Application, the property owner shall maintain a valid operations and maintenance agreement for the life of the OWTS. Pressurized drainfields: An O&M agreement is required to be in place for the life of the system. The first O&M agreement of the system shall be recorded in the Land Evidence records of the pertinent City/Town.” source

Contract for the life of the system
Yes
Homeowner self-maintenance
Not stated
Self-maintenance conditions
Where an Alternative or Experimental Technology approval or the approved OWTS application requires it, the owner must keep a valid O&M agreement for the life of the OWTS; all pressurized drainfields need an O&M agreement for the life of the system, and the first agreement is recorded in the municipal land evidence records (6.36(D), 6.41(I), 6.55(A)). Service frequency and provider qualifications are set in each technology's DEM guidance document.
Reports go to the authority
Yes

250-RICR-150-10-6.41(I)(1)-(2); 6.48(B): “Submit to the Department a certified copy of the recorded contract ... The Department shall not issue a conformance until the documents are recorded. If an operations and maintenance agreement is required pursuant to the terms of the permit a copy of the agreement shall be submitted to the Department with the Certificate of Construction.” source

Report channel
Paper
Report platform
Certified copy of the recorded O&M contract to DEM before the Certificate of Conformance; copy of the O&M agreement submitted with the Certificate of Construction (6.41(I), 6.48(B)); ongoing service reporting is set per technology guidance
Electronic monitoring in the rule
Alarm requirement only

250-RICR-150-10-6.30(B), 6.31(F), 6.36(D): “All pump tanks shall be equipped with sensors and alarms to protect against high water due to failure of the pump or pump controls. All pumps shall be equipped with a high water level, visible and audible alarm powered by a circuit separate from the pump power.” source

Monitoring wording
6.30(B): All pump tanks shall be equipped with sensors and alarms to protect against high water due to failure of the pump or pump controls. 6.31(F): All pumps shall be equipped with a high water level, visible and audible alarm powered by a circuit separate from the pump power. 6.36: control panel with non-resettable elapsed time meters and cycle counters. No telemetry or remote monitoring provision found.
Alarm required
Yes

250-RICR-150-10-6.31(F): “All pumps shall be equipped with a high water level, visible and audible alarm powered by a circuit separate from the pump power.” source

Inspection at sale
None

250-RICR-150-10-6.57(C)(2); R.I. Gen. Laws 23-19.15: “Any cesspool found to be serving a building or use subject to sale or transfer shall be removed or abandoned within twelve (12) months of the date of sale or transfer. Should the manner of wastewater disposal be unknown, an inspection shall be conducted to determine if a cesspool is present on the property. This inspection shall be done by a System Inspector prior to the time of sale or transfer.” source

What triggers it
No general transfer inspection. Cesspool Act: a cesspool serving a building subject to sale or transfer must be removed or abandoned within 12 months of the sale, and if the disposal method is unknown a System Inspector must inspect before the sale or transfer (6.57(C)(2)).
Who inspects
Point-of-sale inspector
Provider list
http://www.dem.ri.gov/programs/benviron/water/licenses/isds/pdfs/deslist.pdf

250-RICR-150-10-6.8(80): “A person on a DEM-approved list (can be found at the following address: http://www.dem.ri.gov/programs/benviron/water/licenses/isds/pdfs/deslist.pdf).” source

Systems in service

YearWhatLowMidHighMethod
1990All systems118,410118,410118,4101990 censussource
2021All systems40,22155,38674,545USGS estimate (2025)source

Pumps and aerators

Estimated systems in Rhode Island with an aerobic treatment unit (aerator), an effluent or dosing pump, or either. How these are estimated

With an aerator
1,500
1,000 to 3,000 · 3% of all systems
With a pump
6,600
3,100 to 13,000 · 12% of all systems
Pump or aerator
7,000
3,400 to 14,000 · 13% of all systems

Control panels: about 7,000 installed (2,900 to 16,000), about 70 new a year and 470 replacements a year. How panels are estimated

CountedAn official count or peer-reviewed estimate of aerobic units exists for this state.

Aerators counted: FAST and SeptiTech about 1,000 of 105,833 systems in the Narragansett Bay watershed, scaled to the state. Pump-only: about 17,000 alternative/experimental systems (11%), many media filters (Advantex 3,740).

Licensed professionals

No roster parsed yet. The state's list: http://www.dem.ri.gov/programs/benviron/water/licenses/isds/pdfs/deslist.pdf

Sources

Model catalog of installed septic hardware, and septic rules, permitting authorities and licensed providers by state and county. Every fact links to its source. Manufacturer photos are linked, not copied.