New York septic rules
New York State Department of Health, Bureau of Water Supply Protection · Residential Onsite Wastewater Treatment Systems (10 NYCRR Part 75, Appendix 75-A). Statute: Public Health Law 201(1)(l). Rule: 10 NYCRR Part 75, Appendix 75-A.
For homeowners in New York
- Local agencies permit septic systems under the state rule (10 NYCRR Part 75, Appendix 75-A). Find yours in the county list below.
- The state rule is silent on maintenance contracts for aerobic units.
Counties
The office that permits septic systems in each county, with the estimated number of systems and how many have an aerator or a pump. ● marks counties whose pump and aerator figures come from county records; the rest spread the state estimate.
What the state rule requires
- Administering body
- NYSDOH sets statewide minimum standards in Appendix 75-A for residential systems under 1,000 gpd; local health departments (county, city, part-county or State district offices) permit under local sanitary codes and may adopt stricter standards; NYSDEC regulates larger and non-residential systems (ECL 17-0701)
Appendix 75-A.1(a), (b)(24), 75-A.2: “This appendix applies to on-site wastewater treatment systems serving residential properties ... in quantities of less than 1,000 gallons per day. 'Local Health Department' - a city, county, or part-county department of health or a State Department of Health district office. A local health department may not adopt standards less stringent than the State standard.” source
- Administration model
- State rule, local agencies permit
- Statute
- Public Health Law 201(1)(l)
- Rule
- 10 NYCRR Part 75, Appendix 75-A
- Maintenance contract for aerobic or advanced units
- Not stated
Appendix 75-A.6(b)(6)(ii)(d): “Absorption areas receiving ETU effluent may be designed with a 33% reduction in the total absorption trench length ... when: (1) ETUs are subject to the jurisdiction of a Responsible Management Entity (RME), or (2) Local sanitary codes or watershed rules or regulations incorporate the requirement to maintain and service the ETU in accordance with the manufacturer's recommendations.” source
- Homeowner self-maintenance
- Not stated
Appendix 75-A.6(b)(6): “ETUs shall have a label indicating compliance with the standards for a Class I unit as described in NSF International Standard 40 or equivalent testing. (No operator or owner maintenance provision.)” source
- Self-maintenance conditions
- Appendix 75-A does not require a service contract for Enhanced Treatment Units; it allows a 33% absorption-trench reduction only where the ETU is under a Responsible Management Entity or local codes require maintenance per the manufacturer (75-A.6(b)(6)(ii)(d)).
- Electronic monitoring in the rule
- Alarm requirement only
Appendix 75-A.7(b)(7)-(8): “Pump chambers shall be equipped with an alarm to indicate malfunction. Pump chambers shall be sized to provide a minimum of one day's design flow storage above the alarm level or a duplex pumping system with audible or visual alarms shall be used.” source
- Monitoring wording
- 75-A.7: Pump chambers shall be equipped with an alarm to indicate malfunction ... sized to provide a minimum of one day's design flow storage above the alarm level or a duplex pumping system with audible or visual alarms shall be used. No telemetry or remote monitoring provision found in the 2010 text.
- Alarm required
- Yes
Appendix 75-A.7(b)(7): “Pump chambers shall be equipped with an alarm to indicate malfunction.” source
Systems in service
| Year | What | Low | Mid | High | Method | |
|---|---|---|---|---|---|---|
| 1990 | All systems | 1,460,873 | 1,460,873 | 1,460,873 | 1990 census | source |
| 2021 | All systems | 1,205,179 | 1,300,573 | 1,405,508 | USGS estimate (2025) | source |
Pumps and aerators
Estimated systems in New York with an aerobic treatment unit (aerator), an effluent or dosing pump, or either. How these are estimated
- With an aerator
- 13,000
- 3,600 to 42,000 · 1% of all systems
- With a pump
- 270,000
- 120,000 to 520,000 · 21% of all systems
- Pump or aerator
- 270,000
- 120,000 to 530,000 · 21% of all systems
Control panels: about 270,000 installed (110,000 to 590,000), about 2,700 new a year and 18,000 replacements a year. How panels are estimated
AssumptionNo state figure was found; a regional assumption with a wide range.
No count found. Northeast prior: elevated sand mounds and pressure systems common (PA, NY); advanced units mostly in nitrogen-sensitive areas.
Licensed professionals
No roster parsed yet.
Sources
- Chautauqua County Pumpers and Contractors List 2024 · Chautauqua County Department of Health and Human Services, pdf
- NYSDEC Design Standards for Intermediate Sized Wastewater Treatment Systems · NYS DEC, pdf
- Appendix 75-A (2010 text, Town of Brunswick copy) · NYS DOH via Town of Brunswick, pdf
- 10 NYCRR Appendix 75-A Wastewater Treatment Standards - Residential Onsite Systems · NYS Department of Health, html
- County Environmental Health Programs · NYS Department of Health, html
- District Environmental Health Programs · NYS Department of Health, html
- Erie County property transfer inspections and design professional list · Erie County Department of Health, html
- Article 19 I/A OWTS Approval List (May 2025) · Suffolk County Department of Health Services, pdf
- Report on I/A OWTS Performance (2016 through 2020-2021 editions) · Suffolk County Department of Health Services, pdf
- Suffolk County Subwatersheds Wastewater Plan (July 2020) · Suffolk County, pdf