Southern Nevada Health District, Environmental Health, Individual Sewage Disposal System (ISDS) Program

Type
Health district
Area served
Clark County (FIPS 32003): all residential ISDS; commercial holding tanks and smaller commercial ISDS under the NDEP MOA
Address
ISDS counter: Southern Nevada Health District Main Facility, 280 S. Decatur Blvd., Las Vegas, NV 89107
Phone
702-759-0660
Permit platform
SNHD Environmental Health Portal (Accela Citizen Access); plan review by appointment
Counties
Clark County

Permits, inspects and regulates all residential septic systems in Clark County and keeps existing-system records (Find My Septic System Plans). Offers septic/well certification for real-estate loans (lender-driven, not a sale mandate). No AB220 (2023) septic-to-sewer program; refers to SNWA Septic to Sewer Conversion Program. Current regulations adopted 1984, revised 2009-02-26; proposed 2025 ISDS and Liquid Waste regulations (hearing noticed for 2025-10-23; adoption not confirmed) would add 5-year ISDS operating permits for all systems and a property transfer inspection.

Local rules

Administering body
Southern Nevada District Board of Health ISDS and Liquid Waste Management Regulations (adopted 1984, revised 2009-02-26)
Administration model
State rule, local agencies permit
Rule
SNHD Regulations Governing ISDS and Liquid Waste Management, Sec. 9.8 (ATU), Sec. 10 (Nitrogen Removal Systems)
Maintenance contract for aerobic or advanced units
Yes, for the life of the system

SNHD ISDS Regulations 10.6.1: “A current contract with a maintenance provider approved by the Health Authority is required for the life of all nitrogen removal septic systems. New property owner (s) shall provide the Health Authority with an updated maintenance contract within thirty (30) days from the close of escrow.” source

Contract for the life of the system
Yes
Reports go to the authority
Yes

SNHD ISDS Regulations 10.6.3: “The maintenance provider shall sample and test for total nitrogen on a quarterly basis ... The maintenance provider shall provide unmodified test results to Health Authority from the testing laboratory.” source

Annual operating permit
Yes

SNHD ISDS Regulations 10.7.1-10.7.2: “An annual nitrogen removal system surveillance fee shall be required ... All nitrogen removal systems shall be inspected by the Health Authority at least once per year” source

Fees and periodic programs
Nitrogen removal systems: maintenance contract for life with an SNHD-approved provider (new owner files updated contract within 30 days of close of escrow), quarterly total-nitrogen sampling reported unmodified to SNHD, annual SNHD surveillance inspection and annual surveillance fee (amount in SNHD EH fee schedule, not read). ATUs must be NSF 40 Class I. Proposed 2025 regulations (not confirmed adopted) would require a Property Transfer Inspection within 90 days before any sale by SNHD or an SNHD-certified inspector (exemption if an approved inspection is within 3 years) and 5-year ISDS operating permits for all systems; pos_inspection left blank until adoption is confirmed.

Model catalog of installed septic hardware, and septic rules, permitting authorities and licensed providers by state and county. Every fact links to its source. Manufacturer photos are linked, not copied.