North Dakota septic rules
North Dakota Department of Environmental Quality, Division of Water Quality · On-Site Wastewater Treatment Systems (installer licensing). Statute: NDCC ch. 23.1-07.1. Rule: NDAC 33.1-21-01 (eff. Aug 1, 2025; amended Jan 1, 2026; permanent rules proposed).
For homeowners in North Dakota
- Depending on the county, either the state agency or a local agency permits septic systems. Find yours in the county list below.
- The state rule is silent on maintenance contracts for aerobic units.
Counties
The office that permits septic systems in each county, with the estimated number of systems and how many have an aerator or a pump. ● marks counties whose pump and aerator figures come from county records; the rest spread the state estimate.
What the state rule requires
- Administering body
- ND DEQ licenses installers and holds exclusive authority to adopt licensing, permitting and inspection rules (NDCC 23.1-07.1-02); local public health units and other political subdivisions are the permitting authorities and apply local codes until DEQ's permanent NDAC 33.1-21 rules take effect
NDCC 23.1-07.1-02; NDAC 33.1-21-01-01: “The department has exclusive authority to adopt rules regarding licensing, permitting, and inspections of onsite wastewater treatment systems as provided by North Dakota Century Code section 23.1-07.1-02. 'Permitting authority' means North Dakota local public health unit, other political subdivision, or ... Installers must get a permit from their local public health unit before starting work.” source
- Administration model
- Mixed: state offices and local agencies
- Statute
- NDCC ch. 23.1-07.1
- Rule
- NDAC 33.1-21-01
- License required
- Yes
NDCC 23.1-07.1-03(1)-(2): “An individual may not engage in the business of installing an onsite wastewater treatment system unless the individual is licensed. An individual is exempt from the licensing requirements of this chapter if the individual is installing an onsite wastewater sewage treatment system on the individual's premises for the individual's use.” source
- License classes
- installer;site_evaluator
Proposed NDAC 33.1-21-01-03(1), (5): “A person wishing to engage in the business of installing systems shall submit an application for a license to the department ... An applicant shall pay the license fee of two hundred dollars ... an additional fee of fifty dollars for a soil assessment endorsement.” source
- Maintenance contract for aerobic or advanced units
- Not stated
Proposed NDAC 33.1-21-01: “No provision on aerobic or advanced treatment maintenance, service contracts or operators in the proposed chapter (searched aerobic, advanced, service, contract).” source
- Homeowner self-maintenance
- Not stated
- Electronic monitoring in the rule
- Alarm requirement only
Proposed NDAC 33.1-21-01 general requirements (10): “Systems utilizing power must have an alarm system installed for pump failure.” source
- Monitoring wording
- Proposed NDAC 33.1-21-01 general requirements (10): Systems utilizing power must have an alarm system installed for pump failure. No telemetry or remote monitoring provision; nothing on aerobic unit maintenance.
- Alarm required
- Yes
Proposed NDAC 33.1-21-01 general requirements (10): “Systems utilizing power must have an alarm system installed for pump failure.” source
- Fees and periodic programs
- Proposed rule: installer license $200 a year plus $50 for a soil assessment endorsement, licenses expire Dec 31; DEQ page says licenses are currently issued at no cost; permit fees set by the local permitting authority. No annual operating permit found.
- Provider list
- https://www.deq.nd.gov/publications/WQ/2_NDPDES/SepticSystems/DEQLicensedSepticSystemInstallers.pdf
NDCC 23.1-07.1: “2026 Annual Active ND Licensed Installer List; installers listed were licensed on or before 10/21/2026.” source
- Effective date
- 2025-08-01
Systems in service
| Year | What | Low | Mid | High | Method | |
|---|---|---|---|---|---|---|
| 1990 | All systems | 66,479 | 66,479 | 66,479 | 1990 census | source |
| 2021 | All systems | 173,624 | 178,806 | 185,080 | USGS estimate (2025) | source |
Pumps and aerators
Estimated systems in North Dakota with an aerobic treatment unit (aerator), an effluent or dosing pump, or either. How these are estimated
- With an aerator
- 5,400
- 1,700 to 15,000 · 3% of all systems
- With a pump
- 39,000
- 18,000 to 74,000 · 22% of all systems
- Pump or aerator
- 41,000
- 19,000 to 80,000 · 23% of all systems
Control panels: about 41,000 installed (16,000 to 88,000), about 410 new a year and 2,700 replacements a year. How panels are estimated
AssumptionNo state figure was found; a regional assumption with a wide range.
No count found. Midwest prior: mounds and pressure systems common (MN 42%, WI mounds 13-41%); discharging aerobic units common in parts of IL, MO, KS, IN.
Licensed professionals
- 344 Installer
Septic companies in North Dakota (343)
Sources
- 2026 Annual Active ND Licensed Installer List · ND DEQ Division of Water Quality, pdf
- First District Health Unit septic inspectors list · First District Health Unit, pdf
- North Dakota Local Public Health Unit Directory · ND Department of Health and Human Services, pdf
- North Dakota Local Public Health Units (county map, 2024) · ND Department of Health and Human Services, image
- ND LPHU Service Matrix (02/2026) · ND Department of Health and Human Services, pdf
- Final Proposed NDAC 33.1-21-01 Onsite Wastewater Treatment Systems · ND DEQ, pdf
- NDCC Chapter 23.1-07.1 Onsite Wastewater Treatment Systems · ND Legislative Council, pdf
- SEPHC 2026 licensed soil classifiers and soil reporters · Fargo Cass Public Health, pdf
- Upper Missouri District Health Unit Septic Code (revised 2022) · Upper Missouri District Health Unit, pdf