North Carolina septic rules
NC Department of Health and Human Services, Division of Public Health, On-Site Water Protection Branch · On-Site Wastewater Program. Statute: G.S. 130A, Art. 11 (130A-333 to 130A-345); G.S. 90A, Art. 5 (contractor and inspector certification). Rule: 15A NCAC 18E (eff. Jan 1, 2024; amended June 1, 2026).
For homeowners in North Carolina
- Local agencies permit septic systems under the state rule (15A NCAC 18E (eff. Jan 1, 2024; amended June 1, 2026)). Find yours in the county list below.
- Aerobic and advanced treatment units must stay under a maintenance contract for as long as the system is in use; 2 service visits a year.
- Homeowners may not maintain their own aerobic unit; a licensed provider must.
- No statewide septic inspection is required when a home is sold.
- Electronic monitoring or telemetry is required for some systems.
Counties
The office that permits septic systems in each county, with the estimated number of systems and how many have an aerator or a pump. ● marks counties whose pump and aerator figures come from county records; the rest spread the state estimate.
What the state rule requires
- Administering body
- NC DHHS Division of Public Health, On-Site Water Protection Branch sets rules and approves products; local health departments (county and district) permit and inspect as authorized agents; NCOWCICB certifies installers, inspectors and evaluators; WPCSOCC certifies subsurface system operators
15A NCAC 18E .0101, .0102(a), .0103 definitions (15), (46), (57), (58): “'Local health department' means any county, district, or other health department authorized to be organized under the General Statutes of North Carolina. 'Installer' means a person authorized to construct, install, or repair a wastewater system in accordance with G.S. 90A, Article 5 and applicable rules of the North Carolina On-Site Wastewater Contractors and Inspectors Certification Board.” source
- Administration model
- State rule, local agencies permit
- Statute
- G.S. 130A, Art. 11 (130A-333 to 130A-345); G.S. 90A, Art. 5
- Rule
- 15A NCAC 18E
- License required
- Yes
G.S. 90A-72(a); G.S. 90A-72(b)(2): “No person shall construct, install, or repair or offer to construct, install, or repair an on-site wastewater system without certification at the required level. Exemption: an owner building a single septic tank with a gravity-fed gravel trench on land the person owns, solely for the person and immediate family.” source
- License classes
- installer;installer_advanced;inspector_pos;site_evaluator;maintenance_provider;inspector_general
G.S. 90A-74(3), 90A-77(a); 21 NCAC 39; 15A NCAC 18E .1304(a): “Effective 1/1/25 installers hold only Grade Level II or Grade Level IV certifications (Grade I holders move to II, Grade III to IV). Point of Sale Inspector applicants need two years at Grade IV, or as an Evaluator or Subsurface Operator. Operators of Type IV-VI systems shall at a minimum be certified as a subsurface operator in accordance with G.S. 90A, Article 3.” source
- Maintenance contract for aerobic or advanced units
- Yes, for the life of the system
15A NCAC 18E .1302(c); .1301(b) Table XXXII: “Prior to the issuance or re-issuance of an OP for an advanced pretreatment system, the owner shall provide to the LHD documentation that a contract for operation and maintenance of the system is in place with a Management Entity. For proprietary advanced pretreatment systems, the contract shall be with either the manufacturer, manufacturer's representative, or a Management Entity authorized in writing by the manufacturer.” source
- Contract for the life of the system
- Yes
- Homeowner self-maintenance
- Not allowed
15A NCAC 18E .1301(b) Table XXXII; .1304(a): “Va - Advanced pretreatment meeting NSF/ANSI 40, TS-I, or TS-II ... Management Entity: Private Certified Operator or Public Management Entity with a Certified Operator. IIa - Conventional system: Owner.” source
- Self-maintenance conditions
- Type IV, V and VI systems (LPP, multi-pump, advanced pretreatment, drip, RWTS) must have a Management Entity that is or employs a subsurface operator certified under G.S. 90A Art. 3 / 15A NCAC 08G; for proprietary advanced pretreatment the O&M contract must be with the manufacturer, its representative, or an ME the manufacturer authorizes in writing. The owner may be the ME only for Type I-III systems (Table XXXII).
- Service visits per year
- 2
15A NCAC 18E .1301(b) Table XXXII, Type Va and Vc: “<= 1,500 gpd - 2/year*; > 1,500 gpd and <= 3,000 gpd - 4/year. *Quarterly Management Entity inspections shall be required for the first year. The quarterly inspections may be reduced to twice a year if the wastewater system is in compliance with all OP conditions after the first year.” source
- Service visits per year (commercial)
- 4
- Reports go to the authority
- Yes
15A NCAC 18E .1304(c), (d), (g): “The Management Entity shall provide a copy of the inspection report ... to the owner, LHD, and manufacturer within 30 days of the system inspection. When inspections indicate the need for system repairs, the Management Entity shall notify the LHD within 48 hours. The Management Entity shall submit the inspection report to the Department centralized data management system.” source
- Report channel
- Online portal
- Report platform
- Department centralized data management system (18E .1304(g)); copy of each inspection report to owner, LHD and manufacturer within 30 days; LHD notified within 48 hours when repairs are needed
- Electronic monitoring in the rule
- Required for some systems
15A NCAC 18E .1103(c); .0103(109); .1602(7): “When telemetry is required in accordance with Sections .0800, .1500, .1600, and .1700 of this Subchapter, the control panel shall be connected to an active phone line, wireless internet router, dedicated cellular line, or another form of telemetry that allows the Management Entity to be notified and respond to alarm conditions. The telemetry shall remain active for the life of the wastewater system.” source
- Monitoring wording
- (109) 'Telemetry' means the ability to contact by phone, email, or another electronic medium. The telemetry unit shall continue alarm notifications to the designated party until the alarm condition is remedied. .1103(c): When telemetry is required in accordance with Sections .0800, .1500, .1600, and .1700 of this Subchapter, the control panel shall be connected to an active phone line, wireless internet router, dedicated cellular line, or another form of telemetry that allows the Management Entity to be notified and respond to alarm conditions. The telemetry shall remain active for the life of the wastewater system. (.1602(7): telemetry required for drip systems with DDF > 1,500 gpd.)
- Alarm required
- Yes
15A NCAC 18E .1103(i): “The pump tank shall have a high-water alarm that shall: (1) be audible and visible to the system users and the Management Entity; (2) have a silencer button ...; (5) remain operable whenever the pump is inoperable.” source
- Inspection at sale
- None
G.S. 90A-71(6); G.S. 90A-77(a): “'Inspection' means an examination of an on-site wastewater system permitted under Article 11 of Chapter 130A that is requested by a lending institution, realtor, prospective homebuyer, or other impacted party as a condition of sale, refinancing, or transfer of title, and that meets minimum requirements set by the Board.” source
- What triggers it
- No statewide transfer inspection. G.S. 90A-71(6) defines an 'inspection' as one requested by a lending institution, realtor, prospective homebuyer or other impacted party as a condition of sale, refinancing or transfer of title, performed by an NCOWCICB-certified point-of-sale inspector.
- Who inspects
- Point-of-sale inspector
- Seller disclosure covers septic
- Yes
G.S. 47E-4(b)(1): “The disclosure statement shall address: (1) The water supply and sanitary sewage disposal system.” source
- Fees and periodic programs
- 18E sets no state annual operating fee; operation permits are issued by the LHD and local fee schedules vary. NCOWCICB certification renewals are annual.
- Approved product list
- https://www.dph.ncdhhs.gov/programs/environmental-health/site-water-protection-branch/site-wastewater-program/approved-site-wastewater-products
15A NCAC 18E Sections .1400-.1700: “The Branch approves proprietary products and systems: aerobic treatment units, septic and pump tanks, risers, effluent filters, media filters and other treatment and dispersal systems.” source
- Provider list
- https://ncowcicb.info/certification-list/
G.S. 90A-73: “Certification holder lists include installer and/or point-of-sale inspector certification; installer level determines the system type a contractor can install.” source
- Effective date
- 2024-01-01
Systems in service
| Year | What | Low | Mid | High | Method | |
|---|---|---|---|---|---|---|
| 1990 | All systems | 1,365,632 | 1,365,632 | 1,365,632 | 1990 census | source |
| 2021 | All systems | 1,685,409 | 1,919,660 | 2,141,155 | USGS estimate (2025) | source |
Pumps and aerators
Estimated systems in North Carolina with an aerobic treatment unit (aerator), an effluent or dosing pump, or either. How these are estimated
- With an aerator
- 12,000
- 5,100 to 32,000 · 1% of all systems
- With a pump
- 290,000
- 140,000 to 550,000 · 15% of all systems
- Pump or aerator
- 300,000
- 140,000 to 570,000 · 16% of all systems
Control panels: about 300,000 installed (120,000 to 620,000), about 11,000 new a year and 20,000 replacements a year. How panels are estimated
State evidenceShares come from the state's permit records or county inventories.
Share: advanced Type V/VI under 1% of operation permits (FY2001-04); Type IV pressure 1-2%; Type III (gravity variants plus single-pump systems) 29-43% is an upper bound for pumped.
- NC On-Site Water Protection county activity totals FY2003-04 · med confidence
Permits issued statewide
| Year | New | Repair | Alteration | Operation permits |
|---|---|---|---|---|
| 2024 | 9,585 | 2,813 | 482 | 12,880 |
| 2023 | 10,296 | 2,773 | 559 | 13,628 |
| 2022 | 12,210 | 3,166 | 776 | 16,152 |
| 2004 | 34,881 | 8,011 | 1,393 | 44,285 |
| 2003 | 33,967 | 6,297 | 1,286 | 41,550 |
| 2002 | 37,775 | 7,291 | 1,360 | 46,426 |
| 2001 | 36,759 | 6,915 | 1,232 | 44,906 |
Licensed professionals
- 4,651 Installer
Septic companies in North Carolina (4,378)
Sources
- North Carolina approved on-site products · NC DHHS, html
- Brunswick County Environmental Health Fee Schedule FY2025-2026 · Brunswick County Environmental Health Services, pdf
- Catawba County licensed septic installers (2025-02-17) and certified septic system operators (2019-06-24) · Catawba County Environmental Health, xlsx
- North Carolina On-Site Water Protection county activity totals 1995-2024 · NC DHHS, xls
- Davidson County Laserfiche WebLink: Environmental Health / On Site Water Protection septic records · Davidson County, html
- 15A NCAC 18E working copy (updated 9/2/2026) · NC DPH, pdf
- Approved On-Site Wastewater Products · NC DPH On-Site Water Protection Branch, html
- On-Site County Activity Reports (County Activity Totals 1995-2024) · NC DPH On-Site Water Protection Branch, xls
- DPH Data Portal: Onsite Wastewater Program dashboards · NC DPH, html
- Environmental Health Staff by County/District (June 2026) · NC DPH, pdf
- Guilford County GIS WaterQuality_WellSeptic feature service · Guilford County GIS / Environmental Health, api
- Iredell County Environmental Health septic permit PDFs · Iredell County Health Department, pdf
- Johnston County septic and well permit lookup · Johnston County Environmental Health, html
- NCOWCICB Certified List by Last Name (9-26-26) · NC On-Site Wastewater Contractors and Inspectors Certification Board, pdf
- North Carolina approved septic tanks · N.C. Department of Health and Human Services, xls
- Regulations Governing Wastewater Treatment and Dispersal Systems in Wake County (amended 2021-11-19) · Wake County Environmental Services, pdf