Maine septic rules
Maine DHHS, Maine Center for Disease Control and Prevention, Drinking Water Program, Subsurface Wastewater Unit · Subsurface Wastewater Program. Statute: 30-A MRS 4211, 4215(4), 4452; 22 MRS 42(3), 42(3-A), 42(3-B); 22-A MRS 205(2). Rule: 10-144 CMR ch. 241 Maine Subsurface Wastewater Disposal Rules (am. 2023-09-23); 10-144 CMR ch. 245 (site evaluators).
For homeowners in Maine
- Local agencies permit septic systems under the state rule (10-144 CMR ch. 241 Maine Subsurface Wastewater Disposal Rules (am. 2023-09-23); 10-144 CMR ch. 245 (site evaluators)). Find yours in the county list below.
- The state rule is silent on maintenance contracts for aerobic units.
- Selling a home triggers a septic inspection statewide.
Counties
The office that permits septic systems in each county, with the estimated number of systems and how many have an aerator or a pump. ● marks counties whose pump and aerator figures come from county records; the rest spread the state estimate.
What the state rule requires
- Administering body
- Maine CDC Subsurface Wastewater Unit adopts the rules, licenses site evaluators, certifies Local Plumbing Inspectors and third-party inspectors and approves products; municipalities' Local Plumbing Inspectors issue permits and inspect, remitting 25% of the minimum permit fee to the state
10-144 CMR 241 Sec. 3.H.1, I.1, J.1-J.7: “The Department is responsible for ensuring the proper administration of the subsurface wastewater disposal rules ... Local jurisdictions have primary responsibility for enforcing rules adopted by the Department ... The LPI enforces the rule, receives permit applications, issues permits, issues notices and orders, and makes required inspections ... certified by the State of Maine as an LPI” source
- Administration model
- State rule, local agencies permit
- Statute
- 30-A MRS 4211, 4215(4), 4216, 4452; 22 MRS 42(3)
10-144 CMR 241 Notes (statutory authority): “It cites 22 MRS 42(3), 42(3-A), and 42(3-B); 30-A MRS 4211, 4215(4), and 4452; and 22-A MRS 205(2).” source
- Rule
- 10-144 CMR ch. 241; ch. 245
- License required
- Yes
10-144 CMR 241 Sec. 4.A.2: “Permit applications must be prepared by a licensed site evaluator for non-engineered systems. Engineered systems may be prepared by a professional engineer or a licensed site evaluator.” source
- License classes
- site_evaluator;inspector_general;inspector_pos;engineer_pe
10-144 CMR 241 Secs. 4.A.2, 3.J.7, 15-17: “Sec. 16 INDEPENDENT THIRD PARTY INSPECTOR CERTIFICATION; Sec. 17 STANDARDS AND PROCEDURES FOR INDEPENDENT THIRD PARTY INSPECTION OF SUBSURFACE WASTEWATER DISPOSAL SYSTEMS ... The LPI must be certified by the State of Maine as an LPI” source
- Maintenance contract for aerobic or advanced units
- Not stated
10-144 CMR 241 Sec. 17.E(6); Sec. 7.K(1): “These devices usually require a maintenance contract as part of their approval. The contract must be reviewed, and the annual maintenance costs included in the inspection report. Sec. 7.K(1): Using an aerobic unit or other device in place of, or with, a septic tank requires prior approval of the device by the Department ... bear the endorsement of the National Sanitation Foundation's Standard 40” source
- Self-maintenance conditions
- Ch. 241 sets no maintenance-contract rule; Sec. 17.E(6) notes advanced treatment devices 'usually require a maintenance contract as part of their approval' (a product-approval condition, not a rule)
- Electronic monitoring in the rule
- Alarm requirement only
10-144 CMR 241 Sec. 7.R(10), S(10); Sec. 17.E(5): “A high-water alarm is required for pump-dosed and siphon-dosed tanks. For pump systems, it must be set 4 inches above the pump-on switch ... When utilized pumps, lift stations, dosing equipment risers, and alarms must be located and inspected.” source
- Monitoring wording
- 10-144 CMR 241 Sec. 7.R(10) and S(10): a high-water alarm is required for pump-dosed and siphon-dosed tanks, 'set 4 inches above the pump-on switch' for pump systems; Sec. 17.E(5): 'pumps, lift stations, dosing equipment risers, and alarms must be located and inspected'. No telemetry, remote or electronic-monitoring provision in Secs. 7, 11 or 17.
- Alarm required
- Yes
10-144 CMR 241 Sec. 7.S(10): “set 4 inches above the pump-on switch” source
- Inspection at sale
- Required statewide
30-A MRS 4216(2)(A)-(D): “The purchaser must have the system inspected before buying. If weather makes a pre-purchase inspection impossible, it must be done within 9 months after transfer. If it malfunctions: it must be repaired or replaced within one year after transfer. Exemptions: installed within 3 years; seller's certified inspection report within 3 years; purchaser certifies replacement within one year.” source
- What triggers it
- Only for systems in the shoreland zone: before a transfer of shoreland property the purchaser must have the system inspected by a Department-certified inspector (or within 9 months if weather prevents it); exempt if installed within 3 years, if the seller provides a certified inspection report under 3 years old, or if the purchaser certifies replacement within one year; a malfunctioning system must be repaired or replaced within one year (30-A MRS 4216(2)). Statewide, the seller must disclose any malfunction in the preceding 180 days (4216(1)).
30-A MRS 4216(1)-(2): “The transferor must give the buyer a written statement as to whether the system has malfunctioned during the 180 days preceding the date of transfer. Inspection by a person certified by the department.” source
- Who inspects
- Point-of-sale inspector
30-A MRS 4216(2)(A); 10-144 CMR 241 Sec. 16: “Who: A person certified by the department.” source
- Seller disclosure covers septic
- Yes
33 MRS 173(3)(A)-(K): “The type of waste disposal system used on the property; tank size and kind, location, malfunctions, installation date; leach field location, malfunctions, installation date; the date of the most recent servicing of the system; the name of the contractor who services the system; for systems within shoreland zones, septic disclosures required by Title 30-A, section 4216.” source
- Annual operating permit
- No
10-144 CMR 241 Sec. 4.C.1-3, Table 4A-4B: “Municipalities keep 75% of the minimum fee and remit the other 25% to the Department ... a complete non-engineered system has a $250 minimum fee, with $62.50 going to the state ... anyone who starts work without a permit must pay double the permit fee.” source
- Fees and periodic programs
- Permit fee minimum $250 for a complete non-engineered system, 75% kept by the municipality and 25% ($62.50) remitted to the state (Sec. 4.C, Table 4A); double fee for work started without a permit; Department review fees in Table 4B (e.g. $100 engineered-system review); no annual fee in ch. 241
- Effective date
- 2023-09-23
Systems in service
| Year | What | Low | Mid | High | Method | |
|---|---|---|---|---|---|---|
| 1990 | All systems | 301,373 | 301,373 | 301,373 | 1990 census | source |
| 2021 | All systems | 339,838 | 356,848 | 373,297 | USGS estimate (2025) | source |
Pumps and aerators
Estimated systems in Maine with an aerobic treatment unit (aerator), an effluent or dosing pump, or either. How these are estimated
- With an aerator
- 3,600
- 1,000 to 11,000 · 1% of all systems
- With a pump
- 74,000
- 35,000 to 140,000 · 21% of all systems
- Pump or aerator
- 75,000
- 35,000 to 140,000 · 21% of all systems
Control panels: about 75,000 installed (30,000 to 160,000), about 740 new a year and 5,000 replacements a year. How panels are estimated
AssumptionNo state figure was found; a regional assumption with a wide range.
No count found. Northeast prior: elevated sand mounds and pressure systems common (PA, NY); advanced units mostly in nitrogen-sensitive areas.
Licensed professionals
No roster parsed yet.
Sources
- City of Auburn Monthly Permit Report · City of Auburn, html
- City of Augusta Bureau of Code Enforcement (statistics tab) · City of Augusta, html
- List of Certified Septic System Inspectors · Maine CDC Drinking Water Program / Subsurface Wastewater Unit, pdf
- List of Certified System Installers · Maine CDC Drinking Water Program / Subsurface Wastewater Unit, pdf
- SSWW permit application search (HHE-200 / HHE-200A) via DocuWare · Maine CDC Subsurface Wastewater Unit, web app
- Local Plumbing Inspectors, LUPC (unorganized) territories only · Maine CDC Drinking Water Program, xlsx
- Maine CDC Subsurface Wastewater Program (plumbing and subsurface wastewater) page · Maine CDC, html
- Subsurface Wastewater Inspections: report to the Legislature under Resolves 2019 ch. 13 (LD 543) · Maine DHHS, pdf
- 10-144 CMR ch. 241 Maine Subsurface Wastewater Disposal Rules (Cornell LII mirror) · Maine DHHS via Cornell LII, html
- 10-144 CMR 241 2023 amendment (Secretary of State filing) · Maine Secretary of State, docx
- 30-A MRS 4216 Transfers of shoreland property · Maine Legislature, html