Maryland septic rules
Maryland Department of the Environment (MDE), Water and Science Administration, Onsite Systems Division · Onsite Sewage Disposal Systems (OSDS) and Bay Restoration Fund BAT program. Statute: Md. Code, Environment 9-1108; 9-1605.2 (Bay Restoration Fund); Title 9 Subtitle 11A (Board of On-Site Wastewater Professionals). Rule: COMAR 26.04.02 (26.04.02.07 BAT); COMAR 26.04.12 (property transfer inspectors).
For homeowners in Maryland
- Local agencies permit septic systems under the state rule (COMAR 26.04.02 (26.04.02.07 BAT); COMAR 26.04.12 (property transfer inspectors)). Find yours in the county list below.
- A maintenance contract is required for an initial period of 2 years after an aerobic unit is installed; 1 service visits a year.
- Homeowners may maintain their own unit after taking an approved course.
- No statewide septic inspection is required when a home is sold.
Counties
The office that permits septic systems in each county, with the estimated number of systems and how many have an aerator or a pump. ● marks counties whose pump and aerator figures come from county records; the rest spread the state estimate.
What the state rule requires
- Administering body
- MDE Onsite Systems Division directs county health departments and local approving authorities that run delegated OSDS permitting; MDE co-reviews systems of 5,000 gpd or more, certifies BAT installers and O&M providers, and runs the Bay Restoration Fund; State Board of On-Site Wastewater Professionals registers/licenses practitioners
MDE Onsite Systems Division page: “The Onsite Systems Division provides technical assistance and direction to county health departments and local approving authorities that run delegated programs for onsite sewage disposal systems and individual wells; co-reviews systems of 5,000 gpd or more; interprets COMAR 26.04.02-26.04.05.” source
- Administration model
- State rule, local agencies permit
- Statute
- Md. Code, Environment 9-1108; 9-1605.2; Title 9 Subtitle 11A
- Rule
- COMAR 26.04.02; 26.04.12
- License required
- Yes
Md. Code Env. 9-11A-15; MDE Onsite Systems page: “Since December 31, 2022, anyone performing onsite wastewater work must register with the State Board of On-Site Wastewater Professionals. Since July 1, 2022, property transfer inspectors must hold a license from the Board.” source
- License classes
- designer;installer;maintenance_provider;pumper;inspector_pos
MDE State Board of On-Site Wastewater Professionals page: “Any individual providing on-site wastewater services must register: design, installation, operation and maintenance, pumping, repair, or property transfer inspection. The Board will eventually categorize licensees as designers, installers, pumpers, inspectors, and operation and maintenance (O&M) providers. MDE also certifies BAT installers and BAT O&M service providers.” source
- Maintenance contract for aerobic or advanced units
- Yes, initial period only
COMAR 26.04.02.07F: “All BAT systems sold in the State shall include a two-year operation and maintenance contract and a two-year warranty, which shall be in effect at the point of initial installation.” source
- Initial contract (years)
- 2
COMAR 26.04.02.07F: “a two-year operation and maintenance contract and a two-year warranty ... in effect at the point of initial installation” source
- Contract for the life of the system
- No
COMAR 26.04.02.07E: “The property owner shall maintain and operate all new and existing BAT systems for the life of the system through one of: a Department-approved responsible management entity, a renewable operating permit, or a certified service provider.” source
- Homeowner self-maintenance
- Allowed after a course
COMAR 26.04.02.07G: “An individual may certify by completing and passing a course of study on operation and maintenance of BAT systems approved by the Department ... A property owner may certify to maintain his own system.” source
- Self-maintenance conditions
- Owner must operate and maintain BAT for the life of the system through an approved responsible management entity, a renewable operating permit, or a certified service provider; a property owner may certify to maintain his own system by completing the Department-approved BAT O&M course
- Service visits per year
- 1
COMAR 26.04.02.07E(3): “Under the certified service provider option, the owner must ensure the system is inspected and has necessary operation and maintenance performed at a minimum of once per year.” source
- Reports go to the authority
- Yes
COMAR 26.04.02.07G, .07I: “Certified service providers must report inspection and O&M activities to the Department yearly. Installers report to the Department within 1 month of installation (address, completion date, BAT type).” source
- Report channel
- Not stated
- Electronic monitoring in the rule
- None found
COMAR 26.04.02.07E(2): “The renewable operating permit option includes enforcement provisions, inspections, and monitoring. No telemetry, remote monitoring or alarm text in 26.04.02.07.” source
- Monitoring wording
- COMAR 26.04.02.07 mentions monitoring only under the operating-permit option (permit includes enforcement provisions, inspections, and monitoring); no telemetry, remote-monitoring or alarm provision found in .07 (rest of chapter 26.04.02 not searched)
- Inspection at sale
- None
COMAR 26.04.12 (administrative history: .01-.07 repealed as emergency provision eff. 2025-11-25, extended to 2026-11-28); MDE Board page: “The on-site wastewater property transfer inspection license will be valid for a 2-year period ... Each inspection requires the Department's standard inspection form, and records must be kept for five years. (No statewide requirement to inspect at transfer found.)” source
- What triggers it
- No state-mandated transfer inspection; MDE board page says property transfer inspectors must be licensed (2-year license, $150) and use the Department's standard inspection form; COMAR 26.04.12 (the PTI license chapter) regulations .01-.07 were repealed by emergency action effective November 25, 2025, extended to November 28, 2026
- Who inspects
- Point-of-sale inspector
- Fees and periodic programs
- $60/yr Bay Restoration Fund fee on septic-served properties (a fund fee, not an operating permit). Bay Restoration Fund fee $5 per month ($60 per year) per onsite system user since July 1, 2012, collected by local billing authorities; Board registration $150; PTI license $150 per 2 years; counties set permit fees
- Approved product list
- https://mde.maryland.gov/programs/water/BayRestorationFund/OnsiteDisposalSystems/Pages/brf_bat.aspx
COMAR 26.04.02.07; MDE BRF BAT page: “BAT Class I (field verified, grant eligible, TN to 30 mg/L or better): Fuji Clean CEN, Orenco AdvanTex RT and AX20, SeptiTech, Hydro-Action AN, Hoot BNR, RetroFAST, Norweco Singulair TNT/Green, AquaKlear. Class II (under verification): MicroFAST, Nitrex, Norweco Hydro-Kinetic 600 FEU, Ecoflo Coco ECDn, Clearstream 500D.” source
- Provider list
- https://mde.maryland.gov/programs/water/BayRestorationFund/OnsiteDisposalSystems/Documents/Onsite%20Systems/OSDS-Registered-Individuals.pdf
MDE Board page: “Individuals who have satisfied the Property Transfer Inspection licensing requirements hold a License; all others are listed as Registered. Separate PDFs list MDE-certified BAT installers and BAT O&M service providers.” source
Systems in service
| Year | What | Low | Mid | High | Method | |
|---|---|---|---|---|---|---|
| 1990 | All systems | 342,523 | 342,523 | 342,523 | 1990 census | source |
| 2021 | All systems | 362,111 | 420,221 | 472,866 | USGS estimate (2025) | source |
| 2024 | All systems | 450,000 | 450,000 | 450,000 | State inventory | source |
| 2024 | With an aerator (aerobic unit) | 16,315 | 16,315 | 16,315 | State inventory | source |
Pumps and aerators
Estimated systems in Maryland with an aerobic treatment unit (aerator), an effluent or dosing pump, or either. How these are estimated
- With an aerator
- 18,000
- 14,000 to 25,000 · 4% of all systems
- With a pump
- 74,000
- 45,000 to 130,000 · 18% of all systems
- Pump or aerator
- 81,000
- 50,000 to 140,000 · 19% of all systems
Control panels: about 81,000 installed (43,000 to 160,000), about 800 new a year and 5,400 replacements a year. How panels are estimated
CountedAn official count or peer-reviewed estimate of aerobic units exists for this state.
Aerators counted: 16,315 Bay Restoration Fund BAT upgrades to June 2024 (mostly ATUs; excludes privately paid units). Pump-only: sand mounds and pressure systems, no count, regional range.
Licensed professionals
- 1,077 Contractor
- 809 Installer
- 280 Point-of-sale inspector
- 214 Maintenance provider
Septic companies in Maryland (1,335)
Sources
- Maryland Best Available Technology (BAT) list · Maryland MDE, html
- Private Consultants Approved to Perform Percolation Tests · Charles County Department of Health, pdf
- Bay Restoration Fund Best Available Technology (BAT) for removing nitrogen from onsite systems · Maryland Department of the Environment, html
- MDE Certified O&M Service Providers for BAT · Maryland Department of the Environment, pdf
- State Board of On-Site Wastewater Professionals · Maryland Department of the Environment, html
- Bay Restoration Fund Advisory Committee annual status reports 2005-2026 · Maryland Department of the Environment, pdf
- Local County Environmental Health Approving Authorities · Maryland Department of the Environment, html
- OSDS Registered Individuals (Board registrants and licensed property transfer inspectors) · Maryland Department of the Environment, pdf