Indiana septic rules
Indiana Department of Health (IDOH), Environmental Public Health Division, Onsite Sewage Disposal Program · Onsite Sewage Systems Program. Statute: IC 16-19-3-4; 16-19-3-5; IC 16-41-25; IC 16-19-3-27. Rule: 410 IAC 6-8.3 (residential); 410 IAC 6-10.1 (commercial); 410 IAC 6-12 (plan review and fees).
For homeowners in Indiana
- Local agencies permit septic systems under the state rule (410 IAC 6-8.3 (residential); 410 IAC 6-10.1 (commercial); 410 IAC 6-12 (plan review and fees)). Find yours in the county list below.
- Aerobic and advanced treatment units must stay under a maintenance contract for as long as the system is in use.
- Homeowners may not maintain their own aerobic unit; a licensed provider must.
- No statewide septic inspection is required when a home is sold.
Counties
The office that permits septic systems in each county, with the estimated number of systems and how many have an aerator or a pump. ● marks counties whose pump and aerator figures come from county records; the rest spread the state estimate.
What the state rule requires
- Administering body
- IDOH writes 410 IAC 6-8.3/6-10.1, approves technologies (TNI) and reviews commercial plans; local health departments (IC 16-20) issue residential construction permits, inspect and may issue operating permits
410 IAC 6-8.3-53(g); IDOH program page: “In accordance with IC 16-41-25-1(a), the local health department shall issue or deny, in writing ... Local health departments handle some residential plan review and permitting under delegation ... Technologies New to Indiana (TNI) require IDOH written approval before local health departments can permit them.” source
- Administration model
- State rule, local agencies permit
- Statute
- IC 16-19-3-4; 16-19-3-5; IC 16-41-25
410 IAC 6-8.3-53(c), (g); 6-8.3-54(a): “In accordance with IC 16-41-25-10 and IC 16-41-25-11, the department or its agent, or the health officer or the health officer's agent, shall be permitted to enter upon all properties ... Local health departments may require written operating permits in accordance with IC 16-19-3-27(b)(2)” source
- Rule
- 410 IAC 6-8.3; 410 IAC 6-10.1; Indiana Standards for Aerobic Treatment Units (2023-10-27)
- License required
- No
410 IAC 6-8.3 (full text); ATU Standard II.D-E, IV.H: “410 IAC 6-8.3 contains no installer licensing or registration provision. ATU Standard: 'Certified Installer: A person certified by the manufacturer to install on-site sewage systems' ... 'Each manufacturer must train and certify every person involved in the design, plan review, permitting, installation, construction, inspection, and maintenance of its technology'.” source
- Maintenance contract for aerobic or advanced units
- Yes, for the life of the system
Indiana Standards for ATUs VII.A; 410 IAC 6-8.3-57(c): “The owner must: 1. Have a signed Operation and Maintenance (O&M) agreement with an authorized service provider, prior to construction permit issuance, that commences at the time the ATU is placed into operation; and 2. Maintain an O&M agreement with an authorized service provider during the life of the ATU. Rule 57(c): must be maintained for the life of the system through an operating permit issued under the provisions of section 54.” source
- Initial contract (years)
- 2
Indiana Standards for ATUs IV.E, IV.L: “the manufacturer of the unit, or authorized representative, must include a 2-year initial service policy in the original purchase price of the unit ... The O&M agreement (initially, the required 2-year service contract)” source
- Contract for the life of the system
- Yes
Indiana Standards for ATUs VII.A.2: “Maintain an O&M agreement with an authorized service provider during the life of the ATU.” source
- Homeowner self-maintenance
- Not allowed
Indiana Standards for ATUs X.A: “O&M of an ATU must be performed by a certified service provider according to the requirements in the manufacturer's O&M program.” source
- Self-maintenance conditions
- O&M of an ATU must be performed by a manufacturer-certified service provider (ATU Standard X.A); owner must hold an O&M agreement with an authorized service provider before the permit and for the life of the ATU (VII.A)
- Reports go to the authority
- Yes
410 IAC 6-8.3-54(d); ATU Standard IV.M: “The owner shall provide the local health department with the following: (1) Written documentation of all scheduled and unscheduled inspection and maintenance within one (1) month of the date performed. (2) A copy of the inspection and maintenance contract. ATU Standard: Each manufacturer or authorized representative must report to the department and LHD failure of an owner to renew an O&M agreement within 30 days of non-renewal.” source
- Report channel
- Not stated
- Report platform
- Under a local operating permit the owner gives the local health department written documentation of all inspection and maintenance within one month and a copy of the inspection and maintenance contract (410 IAC 6-8.3-54(d)); manufacturer reports non-renewal of O&M agreements to IDOH and the LHD within 30 days (ATU Standard IV.M)
- Electronic monitoring in the rule
- Alarm requirement only
410 IAC 6-8.3-65/66; ATU Standard X.D.1: “with controls, and with a high water alarm switch set at a level above the design high water mark. The alarm shall ... include an audible and visible alarm. Service providers must check wastewater level in all tanks and verify proper operation of float and alarm functions.” source
- Monitoring wording
- 410 IAC 6-8.3-65/66: dosing tanks need 'a high water alarm switch set at a level above the design high water mark. The alarm shall ... include an audible and visible alarm'; 6-8.3-63(g): 'A filter alarm may be installed in the septic tank'. ATU Standard X.D.1: service providers 'verify proper operation of float and alarm functions'. No remote, telemetry or electronic-monitoring provision in the rule or the ATU standard.
- Alarm required
- Yes
410 IAC 6-8.3-65: “include an audible and visible alarm” source
- Inspection at sale
- None
410 IAC 6-8.3; Indiana Standards for ATUs (full text search for 'transfer', 'sale'): “Only 'transfer port' between tank compartments appears (6-8.3-60); no property-transfer provision.” source
- What triggers it
- No transfer inspection in 410 IAC 6-8.3 or the ATU standard
- Annual operating permit
- No
410 IAC 6-8.3-54(a)(2): “An operating permit shall be renewed as follows: (A) At least once every three (3) years for on-site sewage systems having components, other than a septic tank, requiring scheduled inspection and maintenance. (B) At least once every five (5) years for all other on-site sewage systems.” source
- Fees and periodic programs
- No state annual fee; local health departments may require operating permits renewed at least every 3 years for systems with components needing scheduled maintenance and every 5 years otherwise (410 IAC 6-8.3-54(a)); IDOH plan review fees in 410 IAC 6-12; no state installer license (LHDs may register installers)
- Approved product list
- https://www.in.gov/health/eph/technology-new-to-indiana/approved-technologies/
IDOH Approved Technologies page: “Secondary Treatment Systems (ATUs): Aero-Stream Eco-Nest, BioMicrobics MicroFAST, E-Z Treat RSF, Fuji Clean CE/CEN, Hydro-Action AP, Infiltrator ECOPOD-N, Jet J-series, Norweco Singulair/Hydro-Kinetic, SludgeHammer S-series (Approved); Quanics and Zoeller project-by-project.” source
- Effective date
- 2012-11-18
Systems in service
| Year | What | Low | Mid | High | Method | |
|---|---|---|---|---|---|---|
| 1990 | All systems | 703,032 | 703,032 | 703,032 | 1990 census | source |
| 2021 | All systems | 927,968 | 1,008,263 | 1,097,635 | USGS estimate (2025) | source |
| 2026 | All systems | 800,000 | 800,000 | 800,000 | State inventory | source |
Pumps and aerators
Estimated systems in Indiana with an aerobic treatment unit (aerator), an effluent or dosing pump, or either. How these are estimated
- With an aerator
- 30,000
- 9,300 to 88,000 · 3% of all systems
- With a pump
- 220,000
- 98,000 to 440,000 · 22% of all systems
- Pump or aerator
- 230,000
- 100,000 to 470,000 · 23% of all systems
Control panels: about 230,000 installed (87,000 to 520,000), about 2,300 new a year and 15,000 replacements a year. How panels are estimated
AssumptionNo state figure was found; a regional assumption with a wide range.
No count found. Midwest prior: mounds and pressure systems common (MN 42%, WI mounds 13-41%); discharging aerobic units common in parts of IL, MO, KS, IN.
Licensed professionals
No roster parsed yet.
Sources
- Allen County Onsite Sewage System Professionals (installation, evaluation, maintenance) · Allen County Department of Health, html
- Allen County Code Title 17 Article 2, On-Site Wastewater Management District fees and operation permits · Allen County Board of Commissioners, pdf
- Indiana approved technologies · Indiana DOH, html
- Clark County 2026 Septic Installer List · Clark County Health Department, pdf
- Harrison County Certified Septic System Installers, Pumpers, and Inspectors · Harrison County Health Department, html
- Approved Technologies New to Indiana (ATUs, components, soil absorption fields, pretreatment) · Indiana Department of Health, html
- Indiana Standards for Aerobic Treatment Units (2023-10-27) · Indiana Department of Health, pdf
- Directory of Indiana Local Health Departments (map and county dropdown; data file /localhealth/includes/health-contact-info.csv) · Indiana Department of Health, csv
- Onsite Sewage Systems Program page (statistics paragraph) · Indiana Department of Health, html
- TRP Approved Ordinances (local onsite sewage ordinances approved under IC 16-19-3-27.8) · Indiana Department of Health, html
- Kosciusko County Septic Installers Listing 2025 · Kosciusko County Health Department, pdf
- La Porte County 2023 Inspector List (property transfer septic inspectors) · La Porte County Health Department, pdf
- Monroe County Septic System Installers · Monroe County Health Department, html
- Morgan County List of Registered Septic Installers · Morgan County Health Department, html
- Porter County 2026 Onsite Sewage System Installers · Porter County Health Department, pdf
- Indiana Registry of Soil Scientists · Purdue University Office of Indiana State Chemist, html
- Steuben County SWCD septic system health and cost-share program · Steuben County Soil and Water Conservation District, html