Delaware septic rules

Delaware Department of Natural Resources and Environmental Control (DNREC), Division of Water, Groundwater Discharges Section · On-Site Wastewater Treatment and Disposal Systems (Septic Systems). Statute: 7 Del. C. ch. 60. Rule: 7 DE Admin. Code 7101 (amended eff. 2014-01-11, 17 DE Reg. 752).

For homeowners in Delaware

  • Delaware Department of Natural Resources and Environmental Control (DNREC), Division of Water, Groundwater Discharges Section issues septic permits directly. Find yours in the county list below.
  • Aerobic and advanced treatment units must stay under a maintenance contract for as long as the system is in use; 2 service visits a year.
  • Homeowners may maintain their own unit after taking an approved course.
  • Selling a home triggers a septic inspection statewide.
  • After a transfer, the new owner has 90 days to put a maintenance contract in place.
  • Electronic monitoring or telemetry is required for some systems.

Counties

The office that permits septic systems in each county, with the estimated number of systems and how many have an aerator or a pump. ● marks counties whose pump and aerator figures come from county records; the rest spread the state estimate.

CountyPermitting authorityPhoneSystems (USGS mid)With an aeratorPump or aeratorLocal rules
Kent CountyDNREC Division of Water, Groundwater Discharges Section (septic: Residential Services Section)302-739-9947 (septic system permits; I/A systems); 302-739-9948 (community wastewater systems); 302-739-9945 (groundwater discharge licenses)25,9452547,908●
New Castle CountyDNREC Division of Water, Groundwater Discharges Section (septic: Residential Services Section)302-739-9947 (septic system permits; I/A systems); 302-739-9948 (community wastewater systems); 302-739-9945 (groundwater discharge licenses)19,0262054,165●
Sussex CountyDNREC Division of Water, Groundwater Discharges Section (septic: Residential Services Section)302-739-9947 (septic system permits; I/A systems); 302-739-9948 (community wastewater systems); 302-739-9945 (groundwater discharge licenses)50,4573,78920,909●

What the state rule requires

Administering body
DNREC Division of Water, Groundwater Discharges Section issues all site evaluations, permits, certificates of completion and licenses statewide (7101 s.3.3 allows a governmental unit to assume its own program; none delegated as of retrieval)

7 DE Admin. Code 7101 s.1.1, 3.3, 6.1: “These Regulations are adopted by the Secretary of the Department of Natural Resources and Environmental Control under and pursuant to the authority set forth in 7 Del.C. Ch. 60. ... Any governmental unit may assume responsibility and authority for administering its own regulatory program for on site wastewater treatment and disposal systems pursuant to 7 Del.C. s.6003(d) if the delegated program establishes standards no less stringent.” source

Administration model
State agency permits directly

DNREC Septic Systems page: “A licensed Class D soil scientist performs a site evaluation and submits a report to the Department for approval. A licensed designer prepares the design and obtains a permit. A licensed Class E contractor installs the system.” source

Statute
7 Del. C. ch. 60
Rule
7 DE Admin. Code 7101
License required
Yes

7 DE Admin. Code 7101 s.4.2: “It shall be necessary to have the Class A, Class B, Class C, Class D, Class E, Class F, Class H and/or Class I licenses in order to engage in the specified activities under Section 4.1 of these Regulations.” source

License classes
site_evaluator;designer;installer;pumper;inspector_pos;inspector_general

7 DE Admin. Code 7101 s.4.1.1-4.1.8: “Class A - Percolation Tester ... Class B - Designer: conventional ... gravity distribution ... Class C - Designer: conventional and innovative/alternative ... and all pressure distribution systems. Class D - Soil Scientist/Site Evaluator ... Class E - System Contractor: construction, repair and installation ... Class F - Liquid Waste Hauler ... Class H - System Inspector: inspection, investigation and data collection ... present operational condition ... Class I - Construction Inspector. Mapped A,D->site_evaluator; B,C->designer; E->installer; F->pumper; H->inspector_pos; I->inspector_general. Certified service provider (ATU O&M) is a certification held by Class E or H licensees or manufacturer representatives, not a separate license.” source

Maintenance contract for aerobic or advanced units
Yes, for the life of the system

7 DE Admin. Code 7101 s.5.5.5, 5.5.5.1, 5.5.5.2: “All innovative/alternative systems have operation and maintenance requirements. ... prior to the Department granting a Certificate of Completion, the permittee, unless certified by the homeowner training program, must enter into a service contract with a certified service provider initially, for a minimum of two (2) years starting at the onset of initial system operation. ... Following the initial two (2) year period, the permittee is required to maintain a service contract for the system by: renewing the existing contract annually, at a minimum, contracting with another certified service provider or being certified by the homeowner training program.” source

Initial contract (years)
2

7 DE Admin. Code 7101 s.5.5.5.1: “must enter into a service contract with a certified service provider initially, for a minimum of two (2) years starting at the onset of initial system operation. For replacement systems, this service contract must be submitted with the permit application.” source

Contract for the life of the system
Yes

7 DE Admin. Code 7101 s.5.5.5.2: “Following the initial two (2) year period, the permittee is required to maintain a service contract for the system by: renewing the existing contract annually, at a minimum, contracting with another certified service provider or being certified by the homeowner training program.” source

Homeowner self-maintenance
Allowed after a course

7 DE Admin. Code 7101 s.2.0 definition of Certified service provider; 5.5.5.1; 5.5.5.2: “A Homeowner who has obtained DNREC individual homeowner service provider certification and has been certified through DNREC approved training on the operation and maintenance of the advanced treatment unit or system. The DNREC homeowner certification allows the homeowner to operate and maintain the system.” source

Self-maintenance conditions
Homeowner may replace the service contract by obtaining DNREC individual homeowner service provider certification through DNREC-approved training on the O&M of the specific advanced treatment unit (7101 definitions, 5.5.5.1, 5.5.5.2)
Service visits per year
2

7 DE Admin. Code 7101 s.5.5.5.1.1.1: “Inspection Frequency/Objective: The service contract must outline that the certified service provider is to inspect the system once every six (6) months or otherwise as approved by the Department.” source

Reports go to the authority
Yes

7 DE Admin. Code 7101 s.5.5.5.1.1.2, 5.5.5.3: “All reports and contract renewals from the previous year shall be submitted by February 1st of each year to the Department. The certified service provider must submit all inspection reports to the Department and permittee. The permittee shall submit any contract renewals as necessary to the Department.” source

Report channel
Not stated

7 DE Admin. Code 7101 s.3.24.1; DNREC licensing page: “In accordance with 29 Del.C. ss.501 et seq., retention of reports or other documents may be paper and/or electronic records.” source

Electronic monitoring in the rule
Required for some systems

7 DE Admin. Code 7101 s.6.3.1.12: “All mechanical tanks, chambers, vaults and pits proposed for a large system must be evaluated to determine if remote sensors/alarms are necessary to identify high water levels in order to avoid overflows. Sensors shall be connected to a notification mechanism that will notify the licensed wastewater operator if a high water level is reached. All lift stations and pumping chambers shall be equipped with remote sensors and notification mechanisms.” source

Monitoring wording
All mechanical tanks, chambers, vaults and pits proposed for a large system must be evaluated to determine if remote sensors/alarms are necessary to identify high water levels in order to avoid overflows. Sensors shall be connected to a notification mechanism that will notify the licensed wastewater operator if a high water level is reached. All lift stations and pumping chambers shall be equipped with remote sensors and notification mechanisms (7101 s.6.3.1.12, large systems of 2,500 gpd or more). Small systems: alarm controls NEMA 4x (5.3.17.13); holding tanks audible and visual alarm at 75% capacity (5.3.18.9.4).
Alarm required
Yes

7 DE Admin. Code 7101 s.5.3.17.13, 5.3.18.9.4, 5.3.30.3.3: “All pump electrical connections and alarm controls shall be NEMA 4x rated corrosion resistant and waterproof. ... Be equipped with both an audible and visual alarm installed on an AC circuit ... to indicate when the contents of the tank are at 75% of capacity.” source

Inspection at sale
Required statewide

7 DE Admin. Code 7101 s.3.31.13, 5.4.6.3.1: “For all properties utilizing an OWTDS that are sold or otherwise transferred to other ownership, the persons must have the system pumped out and inspected by a Class F and Class H licensee, respectively, prior to completion of the sale. An extension will be given to sheriff sales, auctions, short sales and cash sales for a period not to exceed 90 calendar days from date of sale. ... These forms shall be submitted within 72 hours of inspection completion.” source

What triggers it
Sale or other transfer of ownership of any property with an on-site system: tank pumped by a Class F hauler and system inspected by a Class H inspector before completion of sale (90-day extension for sheriff sales, auctions, short sales and cash sales); report to DNREC within 72 hours; waived if the owner shows a licensed operator or an annual service contract with a certified service provider; I/A systems may only be inspected by a Class H licensee certified on that unit

7 DE Admin. Code 7101 s.5.4.6.3.4, 5.4.6.3.18: “If the owner of an individual OWTDS provides proof of a licensed operator or has an annual service contract with a certified service provider then such documentation will fulfill the requirements of 5.4.6.3. ... All Innovative/Alternative systems including advanced treatment unit's (ATU's) and alternative drainfield systems may only be inspected by a Class H licensee that has been certified through DNREC approved training for that ATU or alternative drainfield system.” source

Who inspects
Point-of-sale inspector

7 DE Admin. Code 7101 s.5.4.6.3.2: “Must be performed by a Class H system inspector.” source

Days to a new contract after a transfer
90

7 DE Admin. Code 7101 s.5.5.5.6: “Transferability. Within 90 days after the transfer of the real property which utilizes an innovative/alternative system, the owner shall notify the Department. Transfer of the maintenance agreement must also be completed within this 90 day period.” source

Annual operating permit
No

7 DE Admin. Code 7101 s.5.3.18.10, 3.32.3, 5.5.6: “Each holding tank installed under these Regulations shall be inspected annually. A fee shall be charged for each annual inspection ... the permittee and operator, if applicable, must coordinate with the Department for all annual large system inspections and applicable fees. ... Innovative/Alternative systems without permit conditions requiring a certified service provider shall be inspected by the Department or its designee once every three (3) years and a fee may be required.” source

Fees and periodic programs
No annual operating permit for small conventional systems. Holding tanks inspected annually with an annual inspection fee (5.3.18.10); large systems (2,500 gpd or more) have annual inspections and fees (3.32.3); I/A systems without a certified service provider inspected by DNREC every 3 years, fee may be required (5.5.6). Licenses renew annually by Dec 31 with 10 CE hours.
Approved product list
https://dnrec.delaware.gov/water/residential/septic-systems/approved/

DNREC Septic Systems pages: “Approved Products - General: septic tanks, leaching and dosing chambers, effluent filters, distribution boxes, pre-engineered lift stations, pump and time-dose panels; separate list of innovative and alternative systems (e.g. AdvanTex AX-20) with a Meets PSN3 column.” source

Provider list
https://data.delaware.gov/Energy-and-Environment/Licensed-On-Site-Wastewater-Treatment-and-Disposal/56uc-mvju

DNREC Groundwater Discharge Licenses page: “Licenses are issued for one year and must be renewed before December 31 each year. Renewal requires at least 10 hours of approved continuing education, submitted through Digital DNREC.” source

Effective date
2014-01-11

Systems in service

YearWhatLowMidHighMethod
1990All systems74,54174,54174,5411990 censussource
2021All systems77,06095,428112,794USGS estimate (2025)source

Pumps and aerators

Estimated systems in Delaware with an aerobic treatment unit (aerator), an effluent or dosing pump, or either. How these are estimated

With an aerator
4,200
2,700 to 6,200 · 4% of all systems
With a pump
28,000
21,000 to 38,000 · 30% of all systems
Pump or aerator
30,000
22,000 to 40,000 · 31% of all systems

Control panels: about 30,000 installed (19,000 to 44,000), about 940 new a year and 2,000 replacements a year. How panels are estimated

State evidenceShares come from the state's permit records or county inventories.

Shares from the DNREC permit record (57k-81k built systems): ATU pretreatment 4.4%; LPP 17.8%, mounds 8.6%, pressure dose 3.8%, peat 2.5%, spray 0.6%.

Permits issued statewide

YearNewRepairReplacementAlterationTotalAerobic (spray, drip, ATU)
202665113817241,505131
202569610886241,616146
202488920888141,811124
202385515928131,812136
20221,017301,18432,235185
20211,157201,36372,548262
20201,119191,37562,520247
2019870321,335182,256170
2018951301,282142,279171
2017940211,25982,230130
2016873201,232102,137137
20151,055181,186112,27370
2014995161,093112,11538
20138202989291,75243
20125931481081,42622
201157213693211,30116
20105657672231,26822
200969114584361,32623
20088011766041,55618
20071,32026740132,19823
20061,40429759142,2698
20051,76129695132,55918
20042,177197092,96020
20032,215276202,89212
20022,444246443,15513
20011,973236862,7246
20001,763305672,4047
19991,9251951182,4907
19981,801225482,4224
19971,839125482,4677
19962,165141992,4495
19952,38425602,8046
19941,2342501,6109
19931,14414321,5167
19921,07417591,4211
19912,2249642,909
19902,714973,183
19892,58711723,481
19882,0611212,366
19872,1211202,367
19861,671641,778
198544448

Licensed professionals

Septic companies in Delaware (218)

Sources

Model catalog of installed septic hardware, and septic rules, permitting authorities and licensed providers by state and county. Every fact links to its source. Manufacturer photos are linked, not copied.