Connecticut septic rules

Connecticut Department of Public Health (DPH), Environmental Engineering Program · Subsurface Sewage Disposal Systems (SSDS). Statute: Conn. Gen. Stat. 19a-36 (Public Health Code); 22a-430 (DEEP discharge permits); 20-341a to 20-341m (installer and cleaner licensing). Rule: Conn. Agencies Regs. 19-13-B103a to 19-13-B103f; Technical Standards for Subsurface Sewage Disposal Systems (2024 ed.).

For homeowners in Connecticut

  • Local agencies permit septic systems under the state rule (Conn. Agencies Regs. 19-13-B103a to 19-13-B103f; Technical Standards for Subsurface Sewage Disposal Systems (2024 ed.)). Find yours in the county list below.
  • The state rule is silent on maintenance contracts for aerobic units.
  • No statewide septic inspection is required when a home is sold.

Counties

The office that permits septic systems in each county, with the estimated number of systems and how many have an aerator or a pump. ● marks counties whose pump and aerator figures come from county records; the rest spread the state estimate.

CountyPermitting authorityPhoneSystems (USGS mid)With an aeratorPump or aeratorLocal rules
Fairfield CountyBridgeport Health and Social Services(203) 576-7680 (fax (203) 576-8311)34,1393417,169
Hartford CountyWest Hartford-Bloomfield Health District(860) 561-7900 (fax (860) 561-7918)38,1533828,012
Litchfield CountyTorrington Area Health District(860) 489-0436 (fax (860) 496-8243)44,2504439,292
Middlesex CountyConnecticut River Area Health District(860) 661-3300 (fax HIPAA Protected Fax: (860) 318-2087)28,8982896,069
New Haven CountyTorrington Area Health District(860) 489-0436 (fax (860) 496-8243)31,8033186,679
New London CountyUncas Health District(860) 823-1189 (fax (860) 887-7898)44,2714439,297
Tolland CountyNorth Central District Health Department(860) 745-0383 (fax (860) 745-3188)32,3363236,791
Windham CountyNorth Central District Health Department(860) 745-0383 (fax (860) 745-3188)27,6742775,812

What the state rule requires

Administering body
DPH Environmental Engineering Program sets the Public Health Code and Technical Standards; local directors of health (local health departments and districts) issue approvals to construct and permits to discharge for systems of 7,500 gpd or less (DPH plan approval at 2,000-7,500 gpd); DEEP permits systems over 7,500 gpd, community systems and alternative treatment systems

DPH Environmental Engineering SSDS page; Conn. Agencies Regs. 19-13-B103e; PA 17-146 s.30 (Circular Letter 2017-17): “Systems on sites with design flows of 7,500 GPD and less are permitted by the Local Director of Health. Plans for systems with design flows of 2,000 to 7,500 GPD must be approved by DPH. CT DEEP permits septic systems on sites with design flows above 7,500 GPD, alternative sewage disposal systems, and community sewage systems.” source

Administration model
State rule, local agencies permit

Conn. Agencies Regs. 19-13-B103a, 19-13-B103e(e)(1): “These regulations establish minimum requirements for household and small commercial subsurface sewage disposal systems with a capacity of 5,000 gallons per day or less ... and procedures for the issuance of permits or approvals of such systems by the director of health or registered sanitarian. ... the local director of health shall issue an approval to construct.” source

Statute
Conn. Gen. Stat. 19a-36; 22a-430; 20-341a to 20-341m
Rule
Conn. Agencies Regs. 19-13-B103a to 19-13-B103f; Technical Standards for SSDS (2024 ed., eff. 2024-01-01)
License required
Yes

Conn. Agencies Regs. 19-13-B103e(e)(2): “Each subsurface sewage disposal system shall be constructed by a person licensed Pursuant to section 20-341 of the General Statutes. Such person shall notify the local director of health at least twenty-four hours prior to commencement of construction.” source

License classes
installer;pumper

Conn. Gen. Stat. 20-341a to 20-341m; DPH Environmental Practitioner Licensure page: “Subsurface Sewage Installer and Subsurface Sewage Cleaner licenses; licensure statutes 20-341a through 20-341m; a license is renewed annually; verify a license through the eLicense lookup.” source

Maintenance contract for aerobic or advanced units
Not stated

Technical Standards VIII.E (Proprietary Leaching Systems & Proprietary Pressure-Dosed Dispersal Systems); DEEP UIC page: “Operation and maintenance (O & M) requirements for PPD systems shall be specified by the company and shall be listed on the permit to discharge. Property owners that receive approval for a PPD system shall be required to have O & M on the system by a vendor-trained and authorized individual. Service contracts for routine O & M is typically a requirement for these systems. (Alternative treatment systems fall under DEEP jurisdiction and the Individual Permit.)” source

Homeowner self-maintenance
Not stated

Conn. Agencies Regs. 19-13-B103a-f; Technical Standards 2023: “No provision on owner self-maintenance of treatment units found in 19-13-B103 or the Technical Standards; PPD systems must be maintained by a vendor-trained and authorized individual.” source

Electronic monitoring in the rule
Alarm requirement only

Technical Standards VI.C Pump Systems: “Effluent pump chambers shall be provided with watertight risers/manholes to grade and high-level alarms. The alarm shall be both audible and visual, unless otherwise approved by the DOH, and be located so that it readily alerts building occupants when activated.” source

Monitoring wording
Effluent pump chambers shall be provided with watertight risers/manholes to grade and high-level alarms. The alarm shall be both audible and visual, unless otherwise approved by the DOH, and be located so that it readily alerts building occupants when activated (Technical Standards VI.C). No telemetry, remote or electronic monitoring provision found in 19-13-B103 or the Technical Standards.
Alarm required
Yes

Technical Standards VI.C; X.11: “Effluent pump chambers shall be provided with ... high-level alarms. ... WTW holding tanks shall provide an access cleanout to grade and be equipped with a high-level alarm.” source

Inspection at sale
None

Conn. Agencies Regs. 19-13-B103a-f; Technical Standards 2023 (searched for sale, transfer): “Neither 19-13-B103 nor the Technical Standards contain a requirement to inspect a subsurface sewage disposal system at property sale or transfer; the DPH page lists only voluntary inspection forms (Inspection Cover Page, Inspection Form, Inspection Form Supplement).” source

Seller disclosure covers septic
Yes

Conn. Gen. Stat. 20-327b (Uniform Property Condition Disclosure Act); DCP Residential Property Condition Disclosure Report item 9: “9. Sewage system problems? If yes, explain. Type of sewage disposal system (central sewer, septic, cesspool, etc.)” source

Annual operating permit
No

Conn. Agencies Regs. 19-13-B103e(h); DEEP UIC Individual Wastewater Discharge Permit page: “Permit to discharge issued by the local director of health has no annual renewal or fee provision in 19-13-B103. DEEP individual permit: A non-refundable fee of $4,975.00 (Municipalities receive a 50% discount). Annual Fee: $1,110.00.” source

Fees and periodic programs
No state annual operating permit or fee for household systems under 19-13-B103; local health departments set their own permit fees. DEEP individual wastewater discharge permit (alternative treatment systems, >7,500 gpd): application fee $4,975, annual fee $1,110 (municipalities 50% discount).
Approved product list
https://portal.ct.gov/en/dph/environmental-health/environmental-engineering/environmental-engineering----subsurface-sewage

DPH Environmental Engineering SSDS page: “Non-concrete septic tanks: Valencia Pipe Company (VPC) 1000 and 1500 (approved 7/5/2024). Concrete septic tanks: CT Approved Concrete Septic Tank Suppliers list (11/2018). Proprietary leaching system H-20 certifications: Cur-Tech, Greenleach, Geomatrix, Living Filter.” source

Provider list
https://www.elicense.ct.gov/Lookup/LicenseLookup.aspx

DPH Environmental Practitioner Licensure page: “The page directs users to the eLicense lookup to verify a CT license or certification.” source

Effective date
2024-01-01

Systems in service

YearWhatLowMidHighMethod
1990All systems378,382378,382378,3821990 censussource
2021All systems211,743281,524358,273USGS estimate (2025)source

Pumps and aerators

Estimated systems in Connecticut with an aerobic treatment unit (aerator), an effluent or dosing pump, or either. How these are estimated

With an aerator
2,800
640 to 11,000 · 1% of all systems
With a pump
58,000
22,000 to 130,000 · 21% of all systems
Pump or aerator
59,000
22,000 to 140,000 · 21% of all systems

Control panels: about 59,000 installed (19,000 to 150,000), about 580 new a year and 3,900 replacements a year. How panels are estimated

AssumptionNo state figure was found; a regional assumption with a wide range.

No count found. Northeast prior: elevated sand mounds and pressure systems common (PA, NY); advanced units mostly in nitrogen-sensitive areas.

Licensed professionals

Septic companies in Connecticut (2,059)

Sources

Model catalog of installed septic hardware, and septic rules, permitting authorities and licensed providers by state and county. Every fact links to its source. Manufacturer photos are linked, not copied.