Riverside County Department of Environmental Health, Environmental Protection and Oversight Division, Land Use and Water Resources Program

Type
County
Area served
Unincorporated Riverside County; under MOUs DEH also does planning review and plan check (and OWTS installation inspection in Coachella, Corona, Lake Elsinore, Menifee, Murrieta, Wildomar) for 14 cities; other cities have no formal agreement (LAMP Appendix X)
Address
4080 Lemon St, 10th Floor, Riverside, CA 92501 (Land Use, septic); Indio office 47-950 Arabia St, Suite A, Indio, CA 92201 (760-863-7570)
Phone
951-955-8980
Counties
Riverside County (partial)
Source: https://rivcoeh.org/septic-systems, retrieved 2026-10-31

LAMP (supported by County Ordinance 650): https://rivcoeh.org/sites/g/files/aldnop361/files/migrated/Portals-0-PDF-Land-Use-LAMP-2022.pdf . Revised LAMP approved by Colorado River RWQCB Resolution R7-2024-0039 (2024-11-12). Professionals of Record and Qualified Service Providers must register with DEH (LAMP ch. 4); a certification of the existing system by a registered QSP is required for repairs and modifications. Alternative treatment systems: QSP service agreement and annual QSP inspection with results to DEH within 45 days; ATUs need an annual operating permit; commercial ATS also need a recorded right of entry.

Local rules

Administering body
Riverside County DEH under its LAMP (Tier 2) and Ordinance 650
Administration model
State rule, local agencies permit
Rule
Riverside County LAMP (2022-11-17) ch. 4, 6, 7; Ordinance 650
Maintenance contract for aerobic or advanced units
Yes (term not stated)

Riverside LAMP ch. 6, ATS Operation and Maintenance item 1: “Maintain a service agreement with a QSP trained by the manufacturer. Agreement must be provided prior to final sign-off on the ATS.” source

Homeowner self-maintenance
Not allowed
Self-maintenance conditions
ATS service agreement with a QSP trained by the manufacturer; QSPs register with DEH
Service visits per year
1

Riverside LAMP ch. 6, item 2: “At a minimum, ATS shall be inspected by QSP annually ... The QSP shall provide copies of the inspection results to this Department within 45 days of the date of inspection.” source

Reports go to the authority
Yes
Report channel
Not stated
Electronic monitoring in the rule
Required for some systems
Monitoring wording
LAMP restates OWTS Policy 10.14 for Tier 3 supplemental treatment: visual or audible alarm and a telemetric alarm; owner inspection monthly where telemetry is not possible.
Alarm required
Yes
Inspection at sale
None

Riverside LAMP ch. 7: “An OWTS Certification shall be required for the following: 1. For any repair and/or modifications performed to an existing OWTS. 2. For any new construction/modification on a property that utilizes an OWTS.” source

What triggers it
No sale trigger found; an OWTS Certification by a registered PR/QSP is required for repairs, new construction/modification on a parcel with an OWTS, or projects using an existing OWTS
Annual operating permit
No

Riverside LAMP ch. 6, item 3: “Residential projects shall comply with items 1 and 2. Commercial projects will comply with all items ... A renewable operating permit issued by this Department as required by Ordinance 650.” source

Fees and periodic programs
Commercial ATS: renewable operating permit under Ordinance 650 and recorded right-of-entry; residential ATS: service agreement and annual QSP inspection only

Model catalog of installed septic hardware, and septic rules, permitting authorities and licensed providers by state and county. Every fact links to its source. Manufacturer photos are linked, not copied.