Placer County Health and Human Services, Environmental Health Division

Type
County
Area served
Placer County (Auburn and Tahoe offices)
Address
11434 B Ave, Suite 400, Auburn, CA 95603; Tahoe office 775 N Lake Boulevard, Suite 203, Tahoe City, CA 96145 (530-581-6240)
Phone
530-745-2300

Supplemental treatment systems permitted after 2005-01-01 are in the Operation, Maintenance & Monitoring (OM&M) program: annual maintenance by a service provider, county reminder each November, service due by the end of February, OM&M billing in January; county publishes a Supplemental Treatment Service Providers List (https://www.placer.ca.gov/3313/Operation-Maintenance-Monitoring). Septic permit applications by email to Business@placer.ca.gov. Revised LAMP approved by Central Valley RWQCB Resolution R5-2025-0054 (2025-10-10).

Local rules

Administering body
Placer County Environmental Health under its LAMP (On-Site Sewage Ordinance and Manual), OM&M program
Administration model
State rule, local agencies permit
Rule
Placer County LAMP / On-Site Manual (2017) ch. on OM&M, sections F-H; revised 2025
Maintenance contract for aerobic or advanced units
Yes (term not stated)

Placer On-Site Manual sec. F.1: “The system owner shall sign a maintenance agreement with a certified service provider.” source

Homeowner self-maintenance
Not allowed
Self-maintenance conditions
Annual inspection by a certified OM&M specialist; owner signs a maintenance agreement with a certified service provider
Service visits per year
1

Placer On-Site Manual sec. F.2.a: “Annual inspection by a certified OM&M specialist is required. Proof of inspection shall be submitted in the form of an annual report” source

Reports go to the authority
Yes
Report channel
Not stated
Inspection at sale
None

Placer On-Site Manual sec. F.4: “Renewable operating permits are issued to the system owner and are non-transferable when ownership changes.” source

What triggers it
Renewable operating permits are non-transferable; on change of ownership the Division may review records, inspect the system and brief the new owner before re-issuing
Annual operating permit
Yes

Placer On-Site Manual sec. F.3: “Operating permits are valid for one year, and must be renewed annually.” source

Fees and periodic programs
Renewable operating permit valid one year, renewed annually upon fee and verified OM&M compliance; notice recorded on deed