Los Angeles County Department of Public Health, Environmental Health, Environmental Protection Branch, Land Use Program
- Type
- County
- Area served
- Los Angeles County, unincorporated area and all cities except Long Beach, Pasadena and Vernon (which have their own health officers)
- Address
- 5050 Commerce Drive, Baldwin Park, CA 91706
- Phone
- 626-430-5270
- Counties
- Los Angeles County (partial)
County OWTS web page URL in the old link set returns a not-found page; LAMP read from Lahontan RWQCB copy. Title 11 of the County Code and the Land Use Program's Professional Guide govern OWTS. Point-of-sale inspections by an independent maintenance provider or professional are listed as a voluntary activity with no permit (LAMP Table 4-1). NOWTS (supplemental treatment) require continuous telemetric monitoring, a service contract, a recorded covenant and a Public Health Permit.
Local rules
- Administering body
- Los Angeles County DPH Environmental Health Land Use Program under its LAMP (Tier 2) and County Code Title 11
- Administration model
- State rule, local agencies permit
- Rule
- Los Angeles County LAMP (2018-05-17) sec. 3-4, Table 4-1
- Maintenance contract for aerobic or advanced units
- Yes (term not stated)
LA County LAMP Table 4-1, NOWTS Operation: “Annual Inspection by a qualified septic technician ... Service contract required. Maintenance schedule as specified by manufacturer ... Public Health Permit” source
- Homeowner self-maintenance
- Not allowed
- Self-maintenance conditions
- NOWTS monitored by a service provider certified by the component manufacturer
- Service visits per year
- 1
- Reports go to the authority
- Yes
- Report channel
- Not stated
- Electronic monitoring in the rule
- Required for some systems
LA County LAMP sec. 3 (NOWTS): “The telemetric monitoring system shall be capable of continuously assessing the operation of the supplemental treatment system.” source
- Monitoring wording
- NOWTS shall be equipped with a visual or audible alarm as well as a telemetric alarm that notifies the owner and the service provider of the NOWTS in the event of system malfunction. The telemetric monitoring system shall be capable of continuously assessing the operation of the supplemental treatment system. The owner must enter a covenant with the County prior to approval of the system.
- Alarm required
- Yes
- Inspection at sale
- None
LA County LAMP Table 4-1, Point of Sale Inspections: “Point of Sale Inspections: Code N/A; Inspection of OWTS conducted by independent maintenance provider or professional in conjunction with sale of a property or re-financing; Permit Required N/A” source
- What triggers it
- Point-of-sale inspections by an independent maintenance provider or professional at sale or refinancing are listed with code 'N/A' and permit 'N/A' (not required by the County)
- Annual operating permit
- Yes
- Fees and periodic programs
- NOWTS operation requires a Public Health Permit; annual effluent testing for Tier 3 pathogen areas and in the Lahontan region