Alabama septic rules
Alabama Department of Public Health (ADPH), Division of Community Environmental Protection, Soil and Onsite Sewage Branch · Soil and Onsite Sewage Program. Statute: Code of Ala. 1975 22-26-1 et seq.; 22-25B-1 et seq. (cluster systems); 34-21A-1 et seq. (AOWB licensing). Rule: Ala. Admin. Code ch. 420-3-1 (ADPH); ch. 628-X (AOWB).
For homeowners in Alabama
- Local agencies permit septic systems under the state rule (Ala. Admin. Code ch. 420-3-1 (ADPH); ch. 628-X (AOWB)). Find yours in the county list below.
- The state rule is silent on maintenance contracts for aerobic units.
- No statewide septic inspection is required when a home is sold.
Counties
The office that permits septic systems in each county, with the estimated number of systems and how many have an aerator or a pump. ● marks counties whose pump and aerator figures come from county records; the rest spread the state estimate.
What the state rule requires
- Administering body
- ADPH State Board of Health writes the rules; county health departments (LHDs, ADPH field staff) issue Permits to Install (Repair) and Approvals for Use; ADPH issues performance permits and product permits; Alabama Onsite Wastewater Board licenses installers, pumpers, manufacturers
420-3-1-.06(1); 420-3-1-.05(7): “No person shall begin the installation or repair of an OSS/EDS, or component thereof, until the responsible person has been issued a valid Permit to Install (Repair) an Onsite Sewage System (OSS) by the LHD. ... Any person who installs, repairs, maintains, and/or certifies installation of an OSS/EDS shall be licensed by the AOWB or be exempt from such licensure pursuant to 34-21A-1 et seq., Code of Ala. 1975.” source
- Administration model
- State rule, local agencies permit
- Statute
- Code of Ala. 1975 22-26-1 et seq.; 22-25B-1 et seq.; 34-21A-1 et seq.
420-3-1-.01 Statutory Authority: “Statutory Authority: Code of Ala. 1975, 22-2-2(4); 22-2-2(6); 22-10-1, et seq.; 22-26-1, et seq. (22-25B-1 et seq. added for cluster/wastewater management entity rules)” source
- Rule
- Ala. Admin. Code ch. 420-3-1 (rev. 2/13/2023); ch. 628-X-3
420-3-1-.01 History: “New Rule: Published December 30, 2022; effective February 13, 2023.” source
- License required
- Yes
628-X-3-.01: “Any individual, business, partnership or corporation ... installing, cleaning, pumping, servicing, repairing, or maintaining onsite wastewater equipment or systems in Alabama shall have and maintain a current license issued by the Board or have a licensed employee in responsible charge.” source
- License classes
- installer;installer_advanced;pumper
628-X-3-.01: “The Board shall establish the following types of licenses: A Basic Level Installer's License for ... small flow conventional onsite wastewater systems ... An Advanced Level I Installer's License ... mound systems, simplex pumps with time dosing requirements, on-demand duplex pumps including single family systems with secondary treatment. An Advanced Level II Installers License ... all onsite wastewater systems ... including effluent discharge systems and large flow systems ... A Manufacturer's License ... A Pumper's License ... Portable Toilet License.” source
- Maintenance contract for aerobic or advanced units
- Not stated
420-3-1-.07(1); 420-3-1-.26: “ADPH may issue a permit to a manufacturer of a proprietary treatment or disposal product. These permits shall include conditions and requirements for design, installation, maintenance, and reporting that shall be adhered to by the manufacturer, designers, installers, and users of the products. (No maintenance-contract duration or service frequency for ATS is stated in chapter 420-3-1.)” source
- Homeowner self-maintenance
- Not stated
420-3-1-.05(7); 628-X-3-.01: “Any person who installs, repairs, maintains, and/or certifies installation of an OSS/EDS shall be licensed by the AOWB or be exempt from such licensure pursuant to 34-21A-1 et seq., Code of Ala. 1975.” source
- Report channel
- Not stated
420-3-1-.23(3)(b); 420-3-1-.15(4): “A contract with a licensed sewage tank pumper to include submission of pumping records to the LHD. ... A Performance Permit is an authorization to operate and may contain construction and maintenance requirements, monitoring requirements, reporting requirements, and other requirements as necessary.” source
- Electronic monitoring in the rule
- Alarm requirement only
420-3-1-.23(3)(a); 420-3-1-.27(4): “Permitting conditions shall include the following: (a) A visual or audible alarm. ... The pumping system shall have a high water alarm which shall: (a) Be installed on a separate electrical circuit from the pump. (b) Be rated for the installation location.” source
- Monitoring wording
- Holding tanks: permitting conditions shall include a visual or audible alarm and a contract with a licensed sewage tank pumper to include submission of pumping records to the LHD (420-3-1-.23(3)). Pumped systems: the pumping system shall have a high water alarm on a separate electrical circuit from the pump (420-3-1-.27(4)). No telemetry, remote or electronic monitoring language found; performance permits may contain monitoring requirements (420-3-1-.15(4)).
- Alarm required
- Yes
420-3-1-.27(4): “The pumping system shall have a high water alarm which shall: (a) Be installed on a separate electrical circuit from the pump.” source
- Inspection at sale
- None
420-3-1-.33(1),(3): “When requested by a responsible person or a lending institution representing the seller or buyer, an evaluation of an existing OSS/EDS may be performed by the LHD. ... Before completing the evaluation, the responsible person or the lending institution shall provide evidence that the septic tank of an existing OSS/EDS has been pumped within the last 3 years by an AOWB licensed pumper.” source
- What triggers it
- No transfer inspection required; LHD may evaluate an existing system when requested by the responsible person or a lending institution representing the seller or buyer (420-3-1-.33); tank must have been pumped within 3 years by an AOWB-licensed pumper before the evaluation
- Annual operating permit
- No
420-3-1-.04(72); 420-3-1-.19(5): “Performance Permit -- a permit required for Large-Flow Systems and other systems where effluent monitoring is required to protect the public's health or the environment. This permit may also be referred to as an operational permit. ... An AOWB licensed manufacturer shall submit to the LHD an application for an annual permit by December 31 of each year.” source
- Fees and periodic programs
- No annual operating permit for residential systems; performance (operational) permits only for large-flow, cluster and effluent-monitored systems; ADPH or the LHD may assess permit fees where fee authorization exists (420-3-1-.12(3)); wastewater management entities pay ADPH a quarterly fee of 4 percent of gross income (420-3-1-.16(5))
420-3-1-.12(3); 420-3-1-.16(4)-(5): “ADPH or the LHD may assess a fee where fee authorization exists. ... ADPH is authorized to collect from the wastewater management entity a fee for review of an application for an operational permit ... as provided in Rule 420-1-5-.08 ... Submit to ADPH a quarterly fee equal to 4 percent of its gross income.” source
- Approved product list
- https://www.alabamapublichealth.gov/onsite/publications.html
ADPH Soil and Onsite Sewage Publications page: “Approved Permitted Treatment and Disposal Product Lists, Last Updated: April 2026; about 25 manufacturers with ADPH approval numbers grouped as Treatment-Secondary, Treatment-Tertiary, Disposal and Combined Treatment and Disposal.” source
- Provider list
- https://licensesearch.alabama.gov/AOWB
AOWB home page, Roster Search link: “Roster Search: https://licensesearch.alabama.gov/AOWB” source
- Effective date
- 2023-02-13
Systems in service
| Year | What | Low | Mid | High | Method | |
|---|---|---|---|---|---|---|
| 1990 | All systems | 728,690 | 728,690 | 728,690 | 1990 census | source |
| 2021 | All systems | 1,068,670 | 1,161,532 | 1,249,614 | USGS estimate (2025) | source |
Pumps and aerators
Estimated systems in Alabama with an aerobic treatment unit (aerator), an effluent or dosing pump, or either. How these are estimated
- With an aerator
- 70,000
- 21,000 to 150,000 · 6% of all systems
- With a pump
- 130,000
- 43,000 to 260,000 · 11% of all systems
- Pump or aerator
- 160,000
- 53,000 to 340,000 · 14% of all systems
Control panels: about 160,000 installed (45,000 to 370,000), about 1,600 new a year and 11,000 replacements a year. How panels are estimated
AssumptionNo state figure was found; a regional assumption with a wide range.
No count found. Regional prior (Gulf South); wide range.
Licensed professionals
- 608 Installer
- 504 Pumper
- 416 Installer (advanced)
Septic companies in Alabama (1,184)
Sources
- Ala. Admin. Code Chapter 420-3-1 Onsite Sewage Treatment and Disposal (rev. 2/13/2023) · Alabama Legislature / ADPH, pdf
- Address and Telephone Roster of Public Health Districts and County Health Departments · Alabama Department of Public Health, pdf
- ADPH Soil and Onsite Sewage Branch program pages · Alabama Department of Public Health, html
- ADPH Approved Permitted Treatment and Disposal Product Lists (updated April 2026) · Alabama Department of Public Health, html
- Ala. Admin. Code Chapter 628-X-3 Licensing (Alabama Onsite Wastewater Board), rev. 2/14/2026 · Alabama Onsite Wastewater Board, pdf
- AOWB licensee roster search · Alabama Onsite Wastewater Board / Alabama OIT, web search
- Baldwin County Health Department Existing System Certification Guidelines and request form · Alabama Department of Public Health, Baldwin County, pdf
- Etowah County Health Department Environmental Fee Schedule (effective September 1, 2026) · Alabama Department of Public Health, Etowah County, html
- Jefferson County Board of Health On-Site Sewage Disposal Regulations (adopted March 13, 1996) · Jefferson County Department of Health, pdf
- Mobile County Health Department Environmental Health: Onsite Sewage division and fee list · Mobile County Health Department, html