Anchorage Municipality, Alaska

Who permits septic systems here

Municipality of Anchorage, Development Services, On-Site Water and Wastewater Section

County

Local rules

These add to the state rule on the Alaska page.

Administering body
Municipality of Anchorage Development Services, On-Site Water and Wastewater Section (AMC 15.65)

MOA Wells & Septic page: “the department ... On-Site Water and Wastewater Section; a septic permit is required before a system may be installed or modified within the Municipality of Anchorage” source

Administration model
State rule, local agencies permit

AMC 15.65.005A: “On-site wastewater disposal systems shall conform to the standards in this chapter, 18 AAC 72 and applicable portions of the Uniform Plumbing Code ... When the requirements within this chapter conflict with the requirements of 18 AAC 72 or the UPC, this chapter shall prevail.” source

Rule
Anchorage Municipal Code ch. 15.65 Wastewater Disposal (Part 3 AWWTS, AO 2017-129, eff. 2018-01-23); ch. 15.55 Water Wells
Maintenance contract for aerobic or advanced units
Yes, for the life of the system

AMC 15.65.365A-C: “The installation of an AWWTS requires a maintenance and repair agreement between the municipality and property owner ... the property owner shall enter into a third party service agreement with an AWWTS service provider approved by the manufacturer/manufacturer's representative. A service agreement shall be maintained for the life of the system.” source

Contract for the life of the system
Yes

AMC 15.65.365C: “A service agreement shall be maintained for the life of the system.” source

Homeowner self-maintenance
Not allowed

AMC 15.65.365D.3; 15.65.360D: “The consent of the owner that only maintenance personnel from an approved AWWTS service provider will inspect, maintain and repair the system.” source

Self-maintenance conditions
Owner consents that only maintenance personnel from an approved AWWTS service provider inspect, maintain and repair the system (15.65.365D.3); personnel certified by the manufacturer or its representative (15.65.360D); AWWTS maintenance and repair agreement with the Municipality plus a third-party service agreement for the life of the system (15.65.360B, 15.65.365A-C)
Report channel
Not stated

AMC 15.65.365E: “The maintenance provider shall keep a copy of maintenance records for a period of no less than the past three years and they must provide a copy of the subject records to the MOA if requested.” source

Electronic monitoring in the rule
Required for some systems

AMC 15.65.355C; 15.65.360A: “Category II and III systems that rely on mechanical devices and processes shall be monitored remotely by the equipment provider or other approved entity.” source

Monitoring wording
AMC 15.65.355C: Category II and III systems that rely on mechanical devices and processes shall be monitored remotely by the equipment provider or other approved entity (exception: AWWTS already approved without remote monitoring). 15.65.360A requires routine maintenance and repair of AWWTS and a remote monitoring system; 15.65.365D.6 the owner commits to maintain remote monitoring. 15.65.355H-I allow reduced separation distances for Category II/III units equipped with remote monitoring.
Alarm required
Yes

AMC 15.65.355B: “Any system component utilizing a mechanical device shall be provided with an automatic visual or audible means of notifying the user of the system of a mechanical device failure.” source

Inspection at sale
Required by local ordinance

AMC 15.65.060A: “Prior to the transfer by gift, deed or contract of ownership or use interest in an on-site wastewater disposal system regulated by this chapter, the transferor shall obtain a COSA from the department.” source

What triggers it
Certificate of On-Site Systems Approval (COSA) required before transfer by gift, deed or contract of an interest in a property with an on-site system (AMC 15.65.060A), except transfers between spouses or to a family trust; a registered engineer tests the systems and the septic tank must have been pumped within the past 12 months. A property with an AWWTS also needs a new maintenance and repair agreement with the buyer (15.65.365B).
Who inspects
Professional engineer

MOA COSA Guidelines (rev. April 2025), Introduction: “During the COSA process, a registered professional engineer certifies that any on-site potable water supply system and/or on-site wastewater disposal system meet the code requirements” source

Fees and periodic programs
COSA, permit and certification fees not published on the pages read. AWWTS maintenance providers keep records at least three years and give them to the Municipality on request (15.65.365E).
Source: https://ecode360.com/49392213, retrieved 2026-10-31

Systems in service (estimates)

Model catalog of installed septic hardware, and septic rules, permitting authorities and licensed providers by state and county. Every fact links to its source. Manufacturer photos are linked, not copied.