CurrentClearstream Wastewater Systems, Inc. model 1000N-B, listed to NSF/ANSI 40, rated 1000 gallons per day.
How to identify it
Fiberglass or concrete tank with Clearstream on the plate or molded in the lid. The air pump sits in a housing beside the risers.
- Manufacturer
- Clearstream Wastewater Systems, Inc.
- Manufacturer product page
- No manufacturer page found
- Model
- 1000N-B
- Type
- Treatment unit
- Status
- Current
- NSF standard
- 40
- NSF class
- Class I
- Rated gallons/day
- 1000
- State and NSF listings
- 2
- Look-alike line
- Clearstream Wastewater Systems, Inc. Treatment unit
- Manufacturer site
- clearstreamsystems.com
- Reference
- NSF listing
- Reference
- Texas approval
Control panel
The panel this unit line ships with, from the maker's O&M manual, installation guide or approval letter. "Maker's page" links the panel maker's product page, or the closest page the maker publishes when the panel has none.
| Line | Panel | Controls | Alarm | Timer | Telemetry | Maker's page | Source |
|---|---|---|---|---|---|---|---|
| Clearstream N / NC / NU / D (DA) series | Clearstream Wastewater Systems, Inc. CS-114 series (CS-114A, AP, AT, AN; CS-114F, BP, BT, BN; CS-114C, CS-114D) | aerator; high-level alarm float; discharge pump when used; DA units: timer + solenoid for sludge return | Yes | Yes | Not stated | Maker's panel page | Clearstream Owner's Manual / Operating Manual (DA series, rev 2/28/2023, VDH copy) |